{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RU2116-1HC0-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RU2116-1HC0-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RU2116-1HC0-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RU2116-1HC0-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS thermal overload relay, 3RU2116-1HC0-ZW97, Size S00, Trip Class 10, 690 V rated, spring-loaded terminals, contactor mounting.","salesMarkdown":"Rated for main circuit voltages up to 690 V, this relay carries motor power ratings of 3 kW at 400 V, 4 kW at 500 V, and 5.5 kW at 690 V, with corresponding current ratings of 8 A at both 480 V and 600 V. The auxiliary contact block is integrated and rated for switching: 2 A at 24 V and 230 V, 3 A at 120 V, 1 A at 400 V, and lower currents at higher voltages (0.3 A at 60 V, 0.22 A at 110/125 V, 0.11 A at 220 V). Mounts directly onto a contactor via the fastening method — no separate DIN-rail base required, which saves panel width. Spring-loaded terminals accept 2× (0.5 to 2.5 mm²) solid or stranded wire; use a 3 mm diameter screwdriver with a 3.0 × 0.5 mm tip for the terminal screws. ## Environmental limits The operating frequency is 50/60 Hz. The relay includes an integrated auxiliary switch and a thermal overload release design. The note on the component line reads \"for message 'Tripped'\" — this variant includes a signaling contact that changes state when the relay trips, providing a remote indication to a PLC or annunciator.","metaTitle":"Siemens 3RU2116-1HC0-ZW97 SIRIUS Thermal Overload Relay, Siz","metaDescription":"Siemens 3RU2116-1HC0-ZW97 SIRIUS thermal overload relay, Size S00, Trip Class 10, 690 V rated, contactor mounting. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"Tripped\"","Depth":"70 mm","Width":"45 mm","Height":"87 mm","at 24 V":"2 A","at 60 V":"0.3 A","Per Pole":"2.2 W","at 110 V":"0.22 A","at 120 V":"3 A","at 125 V":"0.22 A","at 220 V":"0.11 A","at 230 V":"2 A","at 400 V":"1 A","Trip Class":"CLASS 10","Rated Value":"690 V","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-40 ... +70 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Contactor mounting","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"thermal overload relay","at 400 V rated value":"3 kW","at 480 V rated value":"8 A","at 500 V rated value":"4 kW","at 600 V rated value":"8 A","at 690 V rated value":"5.5 kW","Size Of Overload Relay":"S00","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-40 ... +60 °C","MTTF with high demand rate":"2 280 y","Design Of Screwdriver Shaft":"Diameter 3 mm","Size Of The Screwdriver Tip":"3,0 x 0,5 mm","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"8 A","at AWG cables for main contacts":"1x (20 ... 12)","For Auxiliary And Control Circuit":"spring-loaded terminals","Between Main And Auxiliary Circuit":"440 V","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 14)","Between Auxiliary And Auxiliary Circuit":"440 V","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Finely Stranded Without Core End Processing":"2x (0.5 ... 1.5 mm²)","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"8g / 11 ms","operational current at AC-3e at 400 V rated value":"8 A","Size Of Contactor Can Be Combined Company-Specific":"S00","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A, quick: 10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","power loss [W] for rated value of the current at AC in hot operating state":"6.6 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"5.5 ... 8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=689158&mlfb=3RU2116-1HC0-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RU2116-1HC0-ZW97/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RU2116-1HC0-ZW97?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What does the 'for message Tripped' note mean on this relay?","answer":"The note indicates this variant includes an auxiliary contact that signals a 'Tripped' status — useful for feeding a remote alarm or PLC input when the overload relay operates."},{"question":"What are the motor power ratings for 3RU2116-1HC0-ZW97?","answer":"At 400 V rated value it carries 3 kW; at 500 V, 4 kW; at 690 V, 5.5 kW. Current ratings at 480 V and 600 V are both 8 A."},{"question":"Does 3RU2116-1HC0-ZW97 comply with RoHS?","answer":"Yes, the substance prohibitance date of October 1, 2009 confirms RoHS compliance for this part."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RU2116-1HC0-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RU2116-1HC0-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}