{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RU2116-1JC0-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RU2116-1JC0-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RU2116-1JC0-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RU2116-1JC0-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RU2116-1JC0-ZX95 thermal overload relay, Size S00, Class 10, spring-loaded terminals, integrated auxiliary contact with trip message, 690 V rated insulation.","salesMarkdown":"## Class 10 trip and what it means on the line The 3RU2116-1JC0-ZX95: If you're protecting a pump or fan motor that hits full speed in a couple seconds, Class 10 is the right call; a Class 20 would let a stalled rotor cook longer before opening. The thermal bimetal release tracks the motor's I²t heating, and the temperature compensation keeps the trip curve accurate from -40 to +60 °C ambient — so it works in an unheated shed or next to a hot conveyor drive without drifting. ## Panel fit — mounts on the contactor, not the rail Size S00 frame mounts directly onto the contactor via the fastening method — no DIN rail needed. That saves a rail slot and keeps the power stack compact. The screwdriver slot is 3.0 x 0.5 mm, so a standard #1 Pozidriv or flat-blade works. ## Auxiliary contact — the trip message signal The 'ZX95' suffix adds an integrated auxiliary contact that changes state on a trip and sends a message — handy for a PLC input or a panel lamp so you know the overload popped without walking the line. Match your control voltage to the table to avoid contact welding on inductive loads. ## Lifecycle and compliance — active, RoHS, no surprises The operating frequency is 50 to 60 Hz, so it works on both 50 Hz European and 60 Hz North American supplies.","metaTitle":"Siemens 3RU2116-1JC0-ZX95 SIRIUS Overload Relay, Class 10","metaDescription":"Siemens 3RU2116-1JC0-ZX95 SIRIUS thermal overload relay, Class 10, Size S00, spring terminals, auxiliary contact with trip message. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"Tripped\"","Depth":"70 mm","Width":"45 mm","title":"3RU2116-1JC0-ZX95","Height":"87 mm","at 24 V":"2 A","at 60 V":"0.3 A","Per Pole":"2.2 W","at 110 V":"0.22 A","at 120 V":"3 A","at 125 V":"0.22 A","at 220 V":"0.11 A","at 230 V":"2 A","at 400 V":"1 A","Trip Class":"CLASS 10","Rated Value":"690 V","description":"Overload relay 7.0...10 A Thermal For motor protection Size S00, Class 10, Contactor mounting Auxiliary circuit: spring-type terminal Auxiliary circuit: spring-type terminal Manual-Automatic-Reset Reusable packaging Pack = 56 units","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-40 ... +70 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Contactor mounting","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"thermal overload relay","at 400 V rated value":"4 kW","at 480 V rated value":"10 A","at 500 V rated value":"5.5 kW","at 600 V rated value":"10 A","at 690 V rated value":"7.5 kW","Size Of Overload Relay":"S00","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-40 ... +60 °C","MTTF with high demand rate":"2 280 y","Design Of Screwdriver Shaft":"Diameter 3 mm","Size Of The Screwdriver Tip":"3,0 x 0,5 mm","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"10 A","at AWG cables for main contacts":"1x (20 ... 12)","For Auxiliary And Control Circuit":"spring-loaded terminals","Between Main And Auxiliary Circuit":"440 V","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 14)","Between Auxiliary And Auxiliary Circuit":"440 V","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Finely Stranded Without Core End Processing":"2x (0.5 ... 1.5 mm²)","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"8g / 11 ms","operational current at AC-3e at 400 V rated value":"10 A","Size Of Contactor Can Be Combined Company-Specific":"S00","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A, quick: 10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","power loss [W] for rated value of the current at AC in hot operating state":"6.6 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"7 ... 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cb98572dd486bf0d88794b1123bd8ea6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=683177&mlfb=3RU2116-1JC0-ZX95"},"ai":{"faq":[{"question":"Where can I buy 3RU2116-1JC0-ZX95 and get a price?","answer":"Available through independent distribution — submit an RFQ with your target quantity."},{"question":"What does the 'ZX95' suffix mean on this overload relay?","answer":"The ZX95 suffix indicates an integrated auxiliary contact with a 'Tripped' message output — it signals the relay has operated, either to a PLC input or a panel indicator."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RU2116-1JC0-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RU2116-1JC0-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}