{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RU2116-4AB0-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RU2116-4AB0-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RU2116-4AB0-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RU2116-4AB0-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RU2116-4AB0-ZX95 thermal overload relay, CLASS 10, Size S00, 690 V rated, screw-type terminals, contactor mounting.","salesMarkdown":"## Trip class and what it means on the line The 3RU2116-4AB0-ZX95: If you're guarding a high-inertia load that needs a longer acceleration ramp, CLASS 10 may trip before the motor is up to speed; you'd step up to CLASS 20 or CLASS 30. ## Size S00 — panel fit and mounting It mounts directly onto the contactor via the fastening method listed as 'contactor mounting', so no separate DIN-rail clip or bracket is needed. ## Auxiliary contact note — 'Tripped' message The relay carries a note: 'for message Tripped'. That means the integrated auxiliary switch is wired to signal a trip condition — not just a standard NO/NC status, but a dedicated 'tripped' indication. On the line, that lets the PLC or HMI display a specific fault message rather than a generic 'overload' alarm, which speeds up troubleshooting.","metaTitle":"Siemens 3RU2116-4AB0-ZX95 Thermal Overload Relay, CLASS 10","metaDescription":"Siemens 3RU2116-4AB0-ZX95 SIRIUS thermal overload relay, CLASS 10 trip, Size S00, 690 V rated. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"Tripped\"","Depth":"70 mm","Width":"45 mm","title":"3RU2116-4AB0-ZX95","Height":"76 mm","at 24 V":"2 A","at 60 V":"0.3 A","Per Pole":"2.7 W","at 110 V":"0.22 A","at 120 V":"3 A","at 125 V":"0.22 A","at 220 V":"0.11 A","at 230 V":"2 A","at 400 V":"1 A","Trip Class":"CLASS 10","Rated Value":"690 V","description":"Overload relay 11...16 A Thermal For motor protection Size S0, Class 10 Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset Reusable packaging Pack = 64 units","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-40 ... +70 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Contactor mounting","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"thermal overload relay","at 400 V rated value":"7.5 kW","at 480 V rated value":"16 A","at 500 V rated value":"7.5 kW","at 600 V rated value":"16 A","at 690 V rated value":"11 kW","Size Of Overload Relay":"S00","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-40 ... +60 °C","MTTF with high demand rate":"2 280 y","Design Of Screwdriver Shaft":"Diameter 5 ... 6 mm","Size Of The Screwdriver Tip":"Pozidriv PZ 2","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"16 A","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Between Main And Auxiliary Circuit":"440 V","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Of The Auxiliary And Control Contacts":"M3","Between Auxiliary And Auxiliary Circuit":"440 V","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"8g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A, quick: 10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","power loss [W] for rated value of the current at AC in hot operating state":"8.1 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"11 ... 16 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ef79793ffa9dad53b792c4e915ba5a4b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=90683&mlfb=3RU2116-4AB0-ZX95"},"ai":{"faq":[{"question":"What is the 3RU2116-4AB0-ZX95's trip class and what does it mean?","answer":"That suits standard motor starts but may be too fast for high-inertia loads."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RU2116-4AB0-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RU2116-4AB0-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}