{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RU6116-1HB1","brand":"Siemens","brandSlug":"siemens","productSlug":"3RU6116-1HB1","canonicalUrl":"https://aoctrl.com/siemens/3RU6116-1HB1","factsUrl":"https://aoctrl.com/api/mcp/products/3RU6116-1HB1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RU6116-1HB1 thermal overload relay, Size S00, adjustable current 5.5-8 A, Trip Class 10, screw-type terminals, standalone installation, 690 V rated voltage, 80 x 45 x 89 mm.","salesMarkdown":"## Motor protection that matches the start-up profile The Siemens 3RU6116-1HB1 is a SIRIUS thermal overload relay sized for motor protection in standalone installations. Rated operational current is 8 A at an operating voltage of 690 V, 50/60 Hz. ## Panel fit and thermal management Total typical power loss is 6 W, with 2.2 W per pole at rated current. Available to order through our distribution channel. We quote against your BOM quantity and confirm lead time and pricing at the time of request. No minimum order restrictions for this active line item.","metaTitle":"Siemens 3RU6116-1HB1 SIRIUS Overload Relay, 5.5-8 A","metaDescription":"Siemens 3RU6116-1HB1 SIRIUS thermal overload relay, adjustable 5.5-8 A, Class 10, Size S00. Screw terminals, standalone mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Overload Relays"],"specifications":{"Depth":"80 mm","Width":"45 mm","title":"3RU6116-1HB1","Height":"89 mm","at 24 V":"2 A","Per Pole":"2.2 W","at 110 V":"0.22 A","at 230 V":"2 A","Trip Class":"CLASS 10","description":"Overload relay 5.5...8.0 A size S00, class 10, for motor protection stand-alone installation main circuit: screw terminal AUX. circuit: screw terminal manual automatic reset","lifecycle_stage":"current","During Operation":"-40 ... +70 °C","During Transport":"-55 ... +80 °C","Fastening Method":"stand-alone installation","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Thermal overload relay","For Main Current Circuit":"screw-type terminals","power loss [W] total typical":"6 W","Operating Voltage Rated Value":"690 V","Substance Prohibitance (Date)":"05/01/2012","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"8 A","at AWG cables for main contacts":"2x (20 ... 16), 2x (20 ... 18), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Relative Humidity During Operation":"0 ... 90 %","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","shock resistance according to IEC 60068-2-27":"8g / 11 ms","Required Spacing For Grounded Parts At The Side":"6 mm","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Tightening Torque For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","insulation voltage with degree of pollution 3 at AC rated value":"690 V","power loss [W] for rated value of the current at AC in hot operating state":"6.6 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"5.5 ... 8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/53dbc2752c902e340ea008547088a39b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621525&mlfb=3RU6116-1HB1"},"ai":{"faq":[{"question":"What is the adjustable current range of the 3RU6116-1HB1?","answer":"The adjustable current response value is 5.5 to 8 A. This range covers standard IEC motor ratings in that band, allowing fine-tuning to match the motor nameplate full-load current."},{"question":"What compliance documentation does Siemens provide for the 3RU6116-1HB1?","answer":"The relay carries a substance prohibitance date of 05/01/2012, indicating RoHS compliance. It is designed to meet IEC standards for industrial control equipment, including surge voltage resistance rated at 6 kV and insulation voltage of 690 V at pollution degree 3."},{"question":"Can I order the 3RU6116-1HB1 and what is the lead time?","answer":"Yes, this part is available to order. We source it through authorized distribution channels and confirm lead time and current pricing at the time of your RFQ. No stock-holding claim is made here — availability is verified per inquiry."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RU6116-1HB1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RU6116-1HB1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}