{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0AA10-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0AA10-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0AA10-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0AA10-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV1011-0AA10-ZW96, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, DIN rail mount.","salesMarkdown":"It's the kind of part that keeps a paper machine running — if this trips cleanly, you find the root cause instead of chasing a cooked motor on a Saturday night. That's a common failure mode in wet environments where a contact or lug corrodes. Dimensions are 45 mm wide, 90 mm tall, 75 mm deep — that's a standard 2.5-module footprint on the rail, so it slots into any existing SIRIUS or third-party MCC layout without re-drilling the gland plate. Clearance: 20 mm upwards and downwards, 9 mm at the sides, zero forwards and backwards. That's tight enough for a dense panel but leaves room for cable bending radius on the screw terminals. Screw-type terminals accept 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) solid or stranded. Main contact screws are M3. ## Environmental range That covers a mill's electrical room in summer and a frozen warehouse in winter without derating.","metaTitle":"Siemens 3RV1011-0AA10-ZW96 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV1011-0AA10-ZW96 SIRIUS motor protection circuit breaker. Class 10 trip, 100 kA breaking capacity at 400 V. Phase failure detection. DIN rail mount. Current lifecycle. Qu","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","title":"3RV1011-0AA10-ZW96","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"none required","at 400 V":"None required","at 500 V":"None required","at 690 V":"None required","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.11...0.16 A N-release 2.1 A screw terminal Standard switching capacity Multi-unit packaging Pack = 48 units","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.16 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.16 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.16 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","at AC-3e at 400 V rated value":"0.16 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.16 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","Electrical Endurance (Operating Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"2.1 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.11 ... 0.16 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dc569b0800fdef12a00c70bc77a5217f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=531991&mlfb=3RV1011-0AA10-ZW96"},"ai":{"faq":[{"question":"What are the key ratings of 3RV1011-0AA10-ZW96?","answer":"Trip Class 10 overload protection, 100 kA breaking capacity at 400 V AC, and built-in phase failure detection. It mounts on 35 mm DIN rail with a 45 mm wide footprint."},{"question":"Will 3RV1011-0AA10-ZW96 drop into a panel specified for 3RV1011-0GA10?","answer":"Both are SIRIUS motor protection circuit breakers in the same 45 mm wide DIN-rail footprint. The -ZW96 variant carries a different factory-set parameter or accessory code; physically it fits the same panel cutout and rail spacing. Confirm the specific trip setting matches your motor FLA before swapping."},{"question":"Where can I buy 3RV1011-0AA10-ZW96 and get current pricing?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What compliance documentation does Siemens provide for 3RV1011-0AA10-ZW96?","answer":"As a standard SIRIUS catalog item, Siemens provides a declaration of conformity to IEC/EN 60947-2 and 60947-4-1, plus RoHS and REACH compliance documentation on request. The product itself carries CE marking for the European market."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0AA10-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0AA10-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}