{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0BA10-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0BA10-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0BA10-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0BA10-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, motor-protective circuit breaker, 3RV1011-0BA10-ZW97, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"The Siemens SIRIUS 3RV1011-0BA10-ZW97 is a motor-protective circuit breaker designed for motor protection, with a Class 10 trip characteristic and a 100 kA breaking capacity at 400 V AC. It mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715, fitting standard panel layouts. ## What the ratings mean for your panel The 100 kA breaking capacity at 400 V AC means this breaker can safely interrupt fault currents up to that level without upstream devices needing to clear the fault — critical for high-fault panels near large transformers. The Class 10 trip clears overloads within 10 seconds at 7.2× rated current, matching standard motor start profiles for pumps and conveyors. Phase failure detection is built in, so a lost phase on the line side trips the breaker rather than letting the motor single-phase and burn. ## Mounting and integration Screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715. Mounting position any. Clearance: 20 mm upwards, 20 mm downwards, 9 mm at the side. Forwards and backwards zero clearance. Screw-type terminals for the main current circuit; terminal capacity 2x (0.5...1.5 mm²) or 2x (0.75...2.5 mm²) solid or stranded. Main contact screw size M3.","metaTitle":"Siemens 3RV1011-0BA10-ZW97 SIRIUS Motor Circuit Breaker, Cla","metaDescription":"Siemens SIRIUS 3RV1011-0BA10-ZW97 motor-protective circuit breaker. Class 10 trip, 100 kA breaking capacity at 400 V AC. Screw/snap-on 35 mm DIN rail. Phase failure detection. Curr","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","title":"3RV1011-0BA10-ZW97","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"none required","at 400 V":"None required","at 500 V":"None required","at 690 V":"None required","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.14...0.2 A N-release 2.6 A screw terminal Standard switching capacity Multi-unit packaging Pack = 24 units","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.2 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.2 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.2 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","at AC-3e at 400 V rated value":"0.2 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.2 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","Electrical Endurance (Operating Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"2.6 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.14 ... 0.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/58de812564fe831f840bf11cfe16f1e0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=499075&mlfb=3RV1011-0BA10-ZW97"},"ai":{"faq":[{"question":"Where can I buy 3RV1011-0BA10-ZW97?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of 3RV1011-0BA10-ZW97 at 400 V?","answer":"100 kA at 400 V AC."},{"question":"Does 3RV1011-0BA10-ZW97 include phase failure protection?","answer":"Yes, phase failure detection is built in."},{"question":"What are the mounting clearances for 3RV1011-0BA10-ZW97?","answer":"20 mm upwards, 20 mm downwards, 9 mm at the side. Zero clearance forwards and backwards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0BA10-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0BA10-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}