{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0BA25","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0BA25","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0BA25","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0BA25","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1011-0BA25 motor-protective circuit breaker, 0.2 A continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw and snap-on DIN rail mount.","salesMarkdown":"The Siemens 3RV1011-0BA25 is a SIRIUS motor-protective circuit breaker, designed to protect motor circuits against overload and short-circuit. Its 0.2 A continuous current rating and CLASS 10 trip class mean it's sized for small fractional-horsepower motors — the CLASS 10 trip curve clears an overload within 10 seconds at 7.2× rated current, matching the thermal time constant of a standard induction motor. It carries a 100 kA breaking capacity across the full AC voltage range (240 V through 690 V), so it can safely interrupt high-fault currents without upstream fuses in most panel designs. Spring-loaded terminals on the main circuit accept 2x (0.25... 2.5 mm²) solid or stranded wire — no lug torque check needed, just strip and push. Any mounting position is allowed, which helps when you're cramming gear into a tight gland plate layout.","metaTitle":"Siemens 3RV1011-0BA25 SIRIUS Motor Circuit Breaker, 0.2 A, C","metaDescription":"Siemens 3RV1011-0BA25 SIRIUS motor-protective circuit breaker, 0.2 A continuous, CLASS 10 trip, 100 kA breaking capacity. Current production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"81 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"90 mm","Maximum":"2 000 m","at 24 V":"1 A","at 60 V":"0.15 A","at 230 V":"0.5 A","Backwards":"0 mm","Trip class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","On The Front":"IP20","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","Auxiliary switch":"Yes","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Shock resistance":"25g / 11 ms","Mounting position":"any","Product brand name":"SIRIUS","Product designation":"circuit breaker","at 400 V rated value":"0.06 kW","Design of the product":"for motor protection","For Auxiliary Contacts":"0","Ground fault detection":"No","Phase failure detection":"Yes","For Main Current Circuit":"spring-loaded terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","Continuous current rated value":"0.2 A","Design of the auxiliary switch":"transverse","at AWG conductors for main contacts":"2x (24 ... 14)","Surge voltage resistance rated value":"6 000 V","at AC in hot operating state per pole":"1.8 W","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Removable Terminal For Auxiliary And Control Circuit":"No","Design of the overcurrent release and short-circuit release":"thermomagnetic","Arrangement of electrical connectors for main current circuit":"front side","Adjustable pick-up value current of the current-dependent overload release":"0.14 ... 0.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=410088&mlfb=3RV1011-0BA25","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0BA25/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the 3RV1011-0BA25?","answer":"100 kA at AC 240 V, 400 V, 500 V, and 690 V — that's a single rating across the board, not derated at higher voltages."},{"question":"What wire size does the 3RV1011-0BA25 accept on the main terminals?","answer":"Spring-loaded terminals accept 2x (0.25... 2.5 mm²) solid or stranded, or 2x (24... 14 AWG)."},{"question":"Does the 3RV1011-0BA25 detect phase failure?","answer":"Yes, phase failure detection is built in — it will trip if one phase drops out."},{"question":"Where can I buy the 3RV1011-0BA25?","answer":"This part is available to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0BA25","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0BA25 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}