{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0CA10-0FJ0-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0CA10-0FJ0-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0CA10-0FJ0-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0CA10-0FJ0-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1011-0CA10-0FJ0-ZX95, motor protection circuit breaker, 0.25 A continuous current, CLASS 10 trip, 100 kA breaking capacity at 400 V, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"## Motor protection circuit breaker for the 0.25 A line Rated short-circuit breaking capacity holds at 100 kA across the voltage range: 240 V, 400 V, 500 V, and 690 V AC. That flat curve means the breaker does not derate its interrupt rating as line voltage rises — unusual for this class, and a strong signal for high-fault-capacity panels. The rated impulse withstand voltage is 6 kV, and surge voltage resistance is rated at 6 000 V, supporting coordination with upstream switchgear. Power dissipation is 5.5 W total in hot operating state, or 1.8 W per pole. For a 45 mm-wide device that is moderate; ensure adjacent devices are not tightly packed without derating if ambient runs above 40 °C. Mounting position is any orientation. Screw-type terminals on the main current circuit accept solid or stranded conductors: 2× (0.5 to 1.5 mm²) and 2× (0.75 to 2.5 mm²), or AWG 18 to 14. Backwards clearance is 0 mm, side clearance 0 mm, so the breaker can be ganged without spacing — useful when filling a DIN rail to the gland plate limit. Front protection is IP20; the enclosure is finger-safe but not washdown-rated.","metaTitle":"Siemens 3RV1011-0CA10-0FJ0-ZX95 SIRIUS Motor Protection Circ","metaDescription":"Siemens SIRIUS 3RV1011-0CA10-0FJ0-ZX95 motor protection circuit breaker, 0.25 A continuous, CLASS 10 trip, 100 kA breaking capacity at 400 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"81 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"45 mm","Height":"90 mm","Maximum":"2 000 m","Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Backwards":"0 mm","Trip class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","On The Front":"IP20","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","Auxiliary switch":"Yes","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Shock resistance":"25g / 11 ms","Mounting position":"any","Product brand name":"SIRIUS","Product designation":"circuit breaker","at 400 V rated value":"0.06 kW","Design of the product":"for motor protection","For Auxiliary Contacts":"0","Ground fault detection":"No","Phase failure detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","Continuous current rated value":"0.25 A","at AWG conductors for main contacts":"2x (18 ... 14)","Surge voltage resistance rated value":"6 000 V","at AC in hot operating state per pole":"1.8 W","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","For Auxiliary And Control Current Circuit":"screw-type terminals","Removable Terminal For Auxiliary And Control Circuit":"No","Design of the overcurrent release and short-circuit release":"thermomagnetic","Arrangement of electrical connectors for main current circuit":"front side","Adjustable pick-up value current of the current-dependent overload release":"0.18 ... 0.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=249276&mlfb=3RV1011-0CA10-0FJ0-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0CA10-0FJ0-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3RV1011-0CA10-0FJ0-ZX95?","answer":"It carries 100 kA breaking capacity at 240 V, 400 V, 500 V, and 690 V AC — a flat curve that does not derate with voltage, which is strong for panel SCCR coordination."},{"question":"What trip class is this motor protection breaker?","answer":"CLASS 10, meaning it trips within 10 seconds at 7.2× rated current, matching standard induction motor startup curves."},{"question":"Does 3RV1011-0CA10-0FJ0-ZX95 include phase failure detection?","answer":"Yes, phase failure detection is built in, preventing single-phasing damage on three-phase motors."},{"question":"Where can I buy 3RV1011-0CA10-0FJ0-ZX95 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers are published here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0CA10-0FJ0-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0CA10-0FJ0-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}