{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0CA10-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0CA10-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0CA10-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0CA10-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1011-0CA10-ZW96 motor circuit breaker, 100 kA breaking capacity at 400 V AC, CLASS 10 trip, screw terminals, 45 x 90 x 75 mm.","salesMarkdown":"It carries a 100 kA breaking capacity at 400 V AC, so it can interrupt a fault up to that level without upstream fuses or a bigger breaker — that's the rating that decides whether it clears a bolted fault on a 400 V line without cascading. CLASS 10 trip curve means it disconnects within 10 seconds at 7.2× the thermal setting, fast enough for standard induction motor starts but not so fast it nuisance-trips on inrush. Dimensions are 45 mm wide, 90 mm tall, 75 mm deep — standard footprint for the SIRIUS 3RV1 frame. Screw terminals for the main circuit accept 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²). No minimum clearance required at 240 V, 400 V, 500 V, or 690 V — spacing is already built into the housing.","metaTitle":"Siemens SIRIUS 3RV1011-0CA10-ZW96 Motor Circuit Breaker, 100","metaDescription":"Siemens SIRIUS 3RV1011-0CA10-ZW96 motor circuit breaker, 100 kA breaking capacity at 400 V AC, CLASS 10 trip, phase failure detection, screw terminals, active production. Quoted to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"none required","at 400 V":"None required","at 500 V":"None required","at 690 V":"None required","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.25 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.25 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.25 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.25 A","Design Of The Short-Circuit Trip":"magnetic","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","Electrical Endurance (Switching Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"3.3 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.18 ... 0.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/55d23af2ee5471276a811b1334130650.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=243634&mlfb=3RV1011-0CA10-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0CA10-ZW96/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV1011-0CA10-ZW96?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of 3RV1011-0CA10-ZW96 at 400 V?","answer":"100 kA at 400 V AC — that is the short-circuit breaking capacity, so it safely interrupts a bolted fault up to that level without upstream protection."},{"question":"Does 3RV1011-0CA10-ZW96 have phase failure detection?","answer":"Yes, phase failure detection is built in. If a phase is lost on the line side, the breaker trips to protect the motor from single-phasing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0CA10-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0CA10-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}