{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0CA10-ZW98","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0CA10-ZW98","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0CA10-ZW98","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0CA10-ZW98","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1011-0CA10-ZW98, motor protection circuit breaker, 45 mm width, 100 kA breaking capacity at 400 V, Trip Class 10, screw-type terminals, DIN rail mount.","salesMarkdown":"It covers a rated voltage range of 20 to 690 V and delivers a 100 kA breaking capacity at 400 V AC — the same rating holds at 240 V, 500 V, and 690 V, so the interrupting performance does not degrade as line voltage rises within that band. Clearance requirements: 20 mm upward, 20 mm downward, 9 mm to the side, and zero forward or backward — so it can sit tight against a backplate or enclosure wall. Motor protection circuit breakers of this class are installed in motor control centers and distribution panels to provide short-circuit and overload protection for individual motor loads — pumps, fans, compressors, conveyors. The combination of thermal overload (Trip Class 10) and magnetic short-circuit release in one device eliminates the need for a separate overload relay and fuse combination on many motor starters.","metaTitle":"Siemens 3RV1011-0CA10-ZW98 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV1011-0CA10-ZW98 motor protection circuit breaker. 100 kA breaking capacity at 400 V, Trip Class 10, phase failure detection, 45 mm wide. Current lifecycle stage.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"none required","at 400 V":"None required","at 500 V":"None required","at 690 V":"None required","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.25 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.25 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.25 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","at AC-3e at 400 V rated value":"0.25 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.25 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","Electrical Endurance (Operating Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"3.3 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.18 ... 0.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=429032&mlfb=3RV1011-0CA10-ZW98","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0CA10-ZW98/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3RV1011-0CA10-ZW98 at 400 V?","answer":"100 kA at 400 V AC, and the same 100 kA rating holds at 240 V, 500 V, and 690 V."},{"question":"Will 3RV1011-0CA10-ZW98 drop into a panel specified around 3RV1011-0GA10 without rewiring?","answer":"Both share the same 45 mm width and DIN rail mounting, so the mechanical fit is identical. Terminal type and wiring capacity should be verified against the existing panel's lugging, but the footprint is interchangeable."},{"question":"How do I get current pricing and availability for 3RV1011-0CA10-ZW98?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; pricing and stock are confirmed at quote time."},{"question":"What compliance documentation does this brand provide for 3RV1011-0CA10-ZW98?","answer":"As a Siemens SIRIUS product, it carries the manufacturer's standard declarations — typically CE, UL, CSA, and RoHS/REACH compliance documentation is available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0CA10-ZW98","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0CA10-ZW98 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}