{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0DA10-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0DA10-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0DA10-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0DA10-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1011-0DA10-ZW96 motor protection circuit breaker, Class 10 trip, 100 kA breaking capacity at 400 V, 45 mm wide, screw terminals, DIN rail mount.","salesMarkdown":"It is part of the SIRIUS family, a modular system for motor control in industrial panels. The 100 kA breaking capacity at 400 V is the headline number: this breaker can safely interrupt a fault current up to 100,000 A at 400 V AC without welding contacts or rupturing the enclosure. That is a high-interrupting rating for a 45 mm wide device, meaning it can be used at the service entrance of a panel with high available fault current — no need for a separate current-limiting fuse upstream in many installations. The rated insulation voltage spans 20 to 690 V, covering most low-voltage motor circuits worldwide. Depth is 75 mm, height 90 mm. Clearance requirements: 20 mm upward, 20 mm downward, 9 mm to the side, zero forward or backward clearance needed. That means it can be mounted flush against the back panel and side walls — useful when packing breakers into a tight enclosure.","metaTitle":"Siemens 3RV1011-0DA10-ZW96 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV1011-0DA10-ZW96 motor protection circuit breaker, Class 10 trip, 100 kA breaking capacity at 400 V, 45 mm wide, DIN rail mount. Current lifecycle stage. Sourced t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","title":"3RV1011-0DA10-ZW96","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"none required","at 400 V":"None required","at 500 V":"None required","at 690 V":"None required","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.22...0.32 A N-release 4.2 A screw terminal Standard switching capacity Multi-unit packaging Pack = 48 units","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.32 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.32 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.32 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","at AC-3e at 400 V rated value":"0.32 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.32 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","Electrical Endurance (Operating Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"4.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.22 ... 0.32 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$33.02","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e9789ef4cce3d86581921355a9001c09.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=68629&mlfb=3RV1011-0DA10-ZW96"},"ai":{"faq":[{"question":"What is the breaking capacity of 3RV1011-0DA10-ZW96 at 400 V?","answer":"100 kA at 400 V AC. The same 100 kA rating applies at 240 V, 500 V, and 690 V."},{"question":"Will 3RV1011-0DA10-ZW96 drop into a panel specified around 3RV1011-0GA10?","answer":"Both are 45 mm wide SIRIUS motor protection breakers with the same DIN rail footprint and screw terminal pattern. The 3RV1011-0GA10 is a different setting range variant; the physical mounting and wiring interface are identical, so a swap requires no panel rework."},{"question":"Where can I buy 3RV1011-0DA10-ZW96 and how is it quoted?","answer":"We source this part through independent distribution channels. Submit an RFQ for current pricing and availability — confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0DA10-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0DA10-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}