{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0DA25","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0DA25","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0DA25","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0DA25","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV1011-0DA25, 0.32 A continuous rated current, Class 10 trip, 100 kA breaking capacity at 400 V AC, spring-loaded terminals, DIN rail mount.","salesMarkdown":"The Siemens SIRIUS 3RV1011-0DA25 is a motor protection circuit breaker sized for small induction motors — 0.32 A continuous current and 0.09 kW at 400 V. The 45 mm width takes one standard module slot; depth is 81 mm, so it clears a 100 mm deep enclosure without issue. Spring-loaded terminals on both main and auxiliary circuits accept 0.25–2.5 mm² solid or stranded (24–14 AWG). No special tools needed beyond a screwdriver for the release lever. The closest functional sibling is the 3RV1011-0GA10. Both are SIRIUS motor protection breakers with the same 45 mm footprint and Class 10 trip. The 0GA10 carries a higher continuous current rating — check your motor FLA before substituting. The 0DA25 is the low-current variant for fractional-horsepower motors; if your BOM calls for 0.32 A, the 0GA10 will not hold the overload curve.","metaTitle":"Siemens 3RV1011-0DA25 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV1011-0DA25 SIRIUS motor protection circuit breaker, 0.32 A continuous rating, Class 10 trip, 100 kA breaking capacity at 400 V. Spring-loaded terminals, DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"81 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"90 mm","at 24 V":"1 A","at 60 V":"0.15 A","at 230 V":"0.5 A","Backwards":"0 mm","Trip Class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Shock Resistance":"25g / 11 ms","Mounting Position":"any","Product Brand Name":"SIRIUS","Product Designation":"circuit breaker","at 400 V rated value":"0.09 kW","Design Of The Product":"for motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"spring-loaded terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"5.5 W","Substance Prohibitance (Date)":"01.01.2013","Continuous Current Rated Value":"0.32 A","Design Of The Auxiliary Switch":"transverse","at AWG cables for main contacts":"2x (24 ... 14)","protection class IP on the front":"IP20","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 000 V","at AWG cables for auxiliary contacts":"2x (24 ... 14)","at AC in hot operating state per pole":"1.8 W","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Touch Protection Against Electrical Shock":"finger-safe","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","number of CO contacts for auxiliary contacts":"0","operational current at AC-3 at 400 V rated value":"0.32 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Design Of The Overcurrent Release And Short-Circuit Release":"thermomagnetic","Arrangement Of Electrical Connectors For Main Current Circuit":"front side","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Mechanical Service Life (Switching Cycles) Of The Main Contacts Typical":"100 000","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.22 ... 0.32 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=205796&mlfb=3RV1011-0DA25","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0DA25/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3RV1011-0DA25 at 400 V?","answer":"100 kA at 400 V AC. That is the same rating across 240 V, 500 V, and 690 V as well — 100 kA symmetrical. This means it can interrupt a fault up to 100,000 amps without welding or rupturing, which covers most industrial service-entrance and MCC applications."},{"question":"Will 3RV1011-0DA25 drop into a panel built for 3RV1011-0GA10?","answer":"Physically yes — same 45 mm width, same DIN rail mount, same spring-loaded terminal layout. The difference is the overload setting: the 0DA25 is set for 0.32 A continuous, the 0GA10 for a higher current. If the motor FLA is 0.32 A, the 0DA25 is the correct part; the 0GA10 would not provide adequate overload protection at that level."},{"question":"How do I get current pricing and availability for 3RV1011-0DA25?","answer":"Submit an RFQ through this listing. The part is sourced and quoted to order through independent distribution; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0DA25","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0DA25 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}