{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0FA10-0FJ0-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0FA10-0FJ0-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0FA10-0FJ0-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0FA10-0FJ0-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1011-0FA10-0FJ0-ZX95 motor-protective circuit breaker, 0.5 A continuous rated current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"## Installation & Environment Shock-rated to 25g for 11 ms, so it holds up in applications with moderate vibration. ## Termination & Wiring Main circuit terminals are screw-type, accepting solid or stranded conductors: 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²), with AWG equivalents 2x (18 to 14). Finely stranded with core end processing uses the same ranges. No auxiliary contacts are included (0 for auxiliary contacts), but the breaker has an auxiliary switch option (yes).","metaTitle":"Siemens 3RV1011-0FA10-0FJ0-ZX95 SIRIUS Motor Protective Circ","metaDescription":"Siemens SIRIUS 3RV1011-0FA10-0FJ0-ZX95 motor-protective circuit breaker, 0.5 A continuous, CLASS 10 trip, 100 kA breaking at 400 V AC. Current lifecycle stage. Sourced to order aga","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"81 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"45 mm","Height":"90 mm","Maximum":"2 000 m","Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Backwards":"0 mm","Trip class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","On The Front":"IP20","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","Auxiliary switch":"Yes","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Shock resistance":"25g / 11 ms","Mounting position":"any","Product brand name":"SIRIUS","Product designation":"circuit breaker","at 400 V rated value":"0.12 kW","Design of the product":"for motor protection","For Auxiliary Contacts":"0","Ground fault detection":"No","Phase failure detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","Continuous current rated value":"0.5 A","at AWG conductors for main contacts":"2x (18 ... 14)","Surge voltage resistance rated value":"6 000 V","at AC in hot operating state per pole":"1.8 W","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","For Auxiliary And Control Current Circuit":"screw-type terminals","Removable Terminal For Auxiliary And Control Circuit":"No","Design of the overcurrent release and short-circuit release":"thermomagnetic","Arrangement of electrical connectors for main current circuit":"front side","Adjustable pick-up value current of the current-dependent overload release":"0.35 ... 0.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=514131&mlfb=3RV1011-0FA10-0FJ0-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0FA10-0FJ0-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV1011-0FA10-0FJ0-ZX95?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of this breaker at 400 V?","answer":"The rated breaking capacity at 400 V AC is 100 kA, meaning it safely interrupts fault currents up to that level without upstream damage."},{"question":"Will 3RV1011-0FA10-0FJ0-ZX95 drop into a panel specified for 3RV1011-0GA10?","answer":"Both share the same SIRIUS family footprint — 45 mm width, 81 mm depth, screw and snap-on mounting on 35 mm DIN rail — so physical fit and rail mounting are identical. The difference is in the trip rating and breaking capacity; verify your load current against the 0.5 A continuous rating of this variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0FA10-0FJ0-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0FA10-0FJ0-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}