{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0FA10-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0FA10-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0FA10-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0FA10-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, motor protection circuit breaker, 3RV1011-0FA10-ZW96, CLASS 10, 100 kA breaking capacity at 400 V, 45 mm width, screw-type terminals.","salesMarkdown":"It is part of the SIRIUS family, a modular system of industrial controls that share a common DIN-rail mounting and accessory platform. No ground-fault detection on this variant, so if that's needed, you'd add a separate module or specify the G version. Depth is 75 mm, height 90 mm. Clearance requirements: 20 mm upwards, 20 mm downwards, 9 mm to the side, zero forwards or backwards. That 9 mm side gap is tight — adjacent breakers can sit nearly flush. Screw-type terminals on the main circuit accept 2× (0.5…1.5 mm²) or 2× (0.75…2.5 mm²) solid or stranded copper. Torque to M3 screw spec. Rated breaking capacity is 100 kA at 240 V, 400 V, 500 V, and 690 V AC. At 690 V, the spec calls for a gL/gG 4 A backup fuse to limit let-through energy — without it, the breaker may not clear a bolted fault at that voltage. This makes it suitable for high-fault panels common in industrial distribution.","metaTitle":"Siemens 3RV1011-0FA10-ZW96 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV1011-0FA10-ZW96 motor protection circuit breaker. CLASS 10 trip, 100 kA breaking capacity at 400 V, 45 mm wide. Phase failure detection, DIN rail mount. Available","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"none required","at 400 V":"None required","at 500 V":"None required","at 690 V":"gL/gG 4 A","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.5 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.5 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.5 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","at AC-3e at 400 V rated value":"0.5 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.5 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","Electrical Endurance (Operating Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"6.5 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.35 ... 0.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7ca32bbd360ac7f58287030933b1bec2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=8082&mlfb=3RV1011-0FA10-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0FA10-ZW96/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV1011-0FA10-ZW96 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing."},{"question":"What is the closest functional second-source — 3RV1011-0GA10?","answer":"The 3RV1011-0GA10 is a peer in the same SIRIUS family and shares the same 45 mm width, CLASS 10 trip, and 100 kA breaking capacity. The key difference is the -0GA10 variant may have a different thermal setting range or auxiliary contact configuration — verify the specific rating plate before substituting. Both mount on the same DIN rail footprint."},{"question":"What is the listed depth of 3RV1011-0FA10-ZW96?","answer":"The depth is 75 mm. Combined with the 45 mm width and 90 mm height, it occupies a standard 2.5-module DIN-rail footprint."},{"question":"Will 3RV1011-0FA10-ZW96 drop into a panel specified around 3RV1011-0GA10 without rewiring?","answer":"The physical footprint is identical — same 45 mm width, same DIN-rail mounting, same screw-terminal layout. The terminal wire ranges are the same (2× 0.5…2.5 mm²). However, the thermal setting range may differ between the two variants, so check the rating plate matches the motor FLA before swapping."},{"question":"What compliance documentation does Siemens provide for this part?","answer":"As a SIRIUS product, Siemens typically provides RoHS, REACH, and UL/CSA/CE declarations. The specific documentation set for this order code should be requested at quote time to confirm it meets your regulatory requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0FA10-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0FA10-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}