{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0FA10-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0FA10-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0FA10-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0FA10-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV1011-0FA10-ZW97, 0.1 kW at 230 V, Trip Class 10, 100 kA breaking capacity, phase failure detection, screw and snap-on DIN rail mount.","salesMarkdown":"Rated at 0.1 kW at 230 V, this breaker is sized for fractional-horsepower motors — think small pumps, fans, or conveyor drives on a 230 V single-phase or three-phase line. The 100 kA breaking capacity at 400 V (and at 240 V, 500 V, and 690 V) means it safely interrupts fault currents up to that level without cascading upstream, which is critical for high-fault-capacity industrial panels where the available short-circuit current can exceed 50 kA. That is the standard DIN rail found in every industrial control panel — no adapter plates needed. Dimensions are 45 mm wide, 90 mm high, 75 mm deep, so it occupies a single 45 mm slot on the rail, leaving room for adjacent contactors or overload relays. Clearance distances are specified: 20 mm upwards, 20 mm downwards, 9 mm to the side, 0 mm forwards and backwards. The forwards/backwards zero clearance means it can be panel-mounted flush against a backplate or enclosure wall without extra air gap, which simplifies panel layout in tight enclosures. Screw-type terminals for the main current circuit accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire, terminated with M3 screws. Strip length and torque values follow standard Siemens practice — typical for panel wiremen familiar with SIRIUS gear. Rated operational voltage spans 20 to 690 V, covering low-voltage motor circuits from control transformers up to 690 V industrial mains. Given its current lifecycle status and broad industrial installed base, supply is generally reliable for both new builds and MRO replacements.","metaTitle":"Siemens 3RV1011-0FA10-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV1011-0FA10-ZW97 SIRIUS motor protection circuit breaker, 0.1 kW at 230 V, Trip Class 10, 100 kA breaking capacity at 400 V, phase failure detection, DIN rail mount. Avai","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"none required","at 400 V":"None required","at 500 V":"None required","at 690 V":"gL/gG 4 A","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.5 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.5 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.5 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.5 A","Design Of The Short-Circuit Trip":"magnetic","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","Electrical Endurance (Switching Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"6.5 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.35 ... 0.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f429e54c3836ed32cc2328d2719a9c1a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=316043&mlfb=3RV1011-0FA10-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0FA10-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RV1011-0FA10-ZW97?","answer":"The depth is 75 mm, with a width of 45 mm and height of 90 mm."},{"question":"What is the breaking capacity of this motor protection circuit breaker?","answer":"The breaking capacity is 100 kA at 240 V, 400 V, 500 V, and 690 V AC, which means it can safely interrupt fault currents up to that level without cascading upstream."},{"question":"Does the 3RV1011-0FA10-ZW97 include phase failure detection?","answer":"Yes, phase failure detection is included, which is essential for protecting three-phase motors from single-phasing damage."},{"question":"What is the Trip Class of this breaker?","answer":"Trip Class 10, meaning the bimetal trip element will open within 10 seconds at 600% of the rated current — matching the thermal characteristics of standard induction motors during start-up."},{"question":"Where can I buy 3RV1011-0FA10-ZW97?","answer":"This part is available to order through independent distribution channels. Submit an RFQ for current pricing and availability — confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0FA10-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0FA10-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}