{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0GA20-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0GA20-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0GA20-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0GA20-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV1011-0GA20-ZX95, 0.63 A rated continuous current, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw and snap-on 35 mm DIN rail mount.","salesMarkdown":"Main contacts terminate via spring-loaded terminals, accepting 2x (0.25... 2.5 mm²) solid or 2x (0.25... 1.5 mm²) finely stranded with ferrule. IP20 on the front keeps fingers out of the live terminals in an enclosed panel. ## Dimensional fit and panel integration The 3RV1011-0GA20-ZX95 occupies 45 mm width, 90 mm height, and 81 mm depth. ## Environmental and electrical margins Shock rated at 25 g for 11 ms — survives the ride to site and the occasional panel door slam. Surge voltage resistance is 6 kV, which covers the impulse withstand for 400 V class installations per IEC 60947-2. Power dissipation at rated current is 5.5 W total, 1.8 W per pole — negligible for panel thermal budgeting at this 0.63 A level.","metaTitle":"Siemens 3RV1011-0GA20-ZX95 SIRIUS Motor Protection CB, 0.63","metaDescription":"Siemens SIRIUS 3RV1011-0GA20-ZX95 motor protection circuit breaker, 0.63 A continuous, Class 10 trip, 100 kA breaking capacity at 400 V. Current production. Quoted to order against","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"81 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"90 mm","Maximum":"2 000 m","Backwards":"0 mm","Trip class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","On The Front":"IP20","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","Auxiliary switch":"Yes","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Shock resistance":"25g / 11 ms","Mounting position":"any","Product brand name":"SIRIUS","Product designation":"circuit breaker","at 400 V rated value":"0.18 kW","Design of the product":"for motor protection","For Auxiliary Contacts":"0","Ground fault detection":"No","Phase failure detection":"Yes","For Main Current Circuit":"spring-loaded terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","Continuous current rated value":"0.63 A","at AWG conductors for main contacts":"2x (24 ... 14)","Surge voltage resistance rated value":"6 000 V","at AC in hot operating state per pole":"1.8 W","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","For Auxiliary And Control Current Circuit":"spring-loaded terminals","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Removable Terminal For Auxiliary And Control Circuit":"No","Design of the overcurrent release and short-circuit release":"thermomagnetic","Arrangement of electrical connectors for main current circuit":"front side","Adjustable pick-up value current of the current-dependent overload release":"0.45 ... 0.63 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=104855&mlfb=3RV1011-0GA20-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0GA20-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Will 3RV1011-0GA20-ZX95 drop into a panel specified around 3RV1011-0GA10 without rewiring?","answer":"Yes, the 45 mm width and DIN rail mounting are identical across the 3RV1011 family. The terminal type — spring-loaded terminals — is the same. The difference is the 0.63 A continuous current rating versus the 3RV1011-0GA10's different setting; verify that the motor FLA matches this breaker's rating before swapping."},{"question":"Where can I buy 3RV1011-0GA20-ZX95 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here."},{"question":"What is the breaking capacity of 3RV1011-0GA20-ZX95 at 400 V?","answer":"100 kA at 400 V AC, and the same 100 kA rating holds at 240 V, 500 V, and 690 V. That covers most industrial distribution fault levels without needing a current-limiting upstream device."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0GA20-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0GA20-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}