{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0HA10-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0HA10-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0HA10-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0HA10-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, motor protection circuit breaker, 3RV1011-0HA10-ZX95, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw-type terminals, 45 x 90 x 75 mm.","salesMarkdown":"It is part of the SIRIUS family, a modular system for motor feeders and control circuits. Includes phase failure detection — if one phase drops out, the breaker trips faster than a standard thermal overload, preventing single-phasing damage to the motor winding. Dimensions: 45 mm wide, 90 mm tall, 75 mm deep. The ZX95 variant carries a special customer-specific code; mechanically it shares the same footprint as the base 3RV1011-0HA10, so it drops into an existing panel layout without rewiring. Screw-type terminals on the main circuit accept 2x (0.5...1.5 mm²) solid or stranded, or 2x (0.75...2.5 mm²). M3 screws for the main contacts. Mounting position any. Clearance spacings: 20 mm upwards, 20 mm downwards, 9 mm at the side, zero forwards or backwards. No external fuse required at 240 V or 400 V; at 500 V or 690 V, use a gL/gG 6 A backup fuse.","metaTitle":"Siemens 3RV1011-0HA10-ZX95 SIRIUS Motor Protection Breaker,","metaDescription":"Siemens SIRIUS 3RV1011-0HA10-ZX95 motor protection circuit breaker. Trip Class 10, 100 kA breaking capacity at 400 V AC. Phase failure detection. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"none required","at 400 V":"None required","at 500 V":"gL/gG 6 A","at 690 V":"gL/gG 6 A","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.8 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.8 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.8 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","at AC-3e at 400 V rated value":"0.8 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.8 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","Electrical Endurance (Operating Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.55 ... 0.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5143eca30fe5baaf4c4244deab4469b0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=205431&mlfb=3RV1011-0HA10-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0HA10-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Will 3RV1011-0HA10-ZX95 drop into a panel specified around 3RV1011-0HA10 without rewiring?","answer":"Yes. The ZX95 suffix is a customer-specific code; the mechanical footprint, terminal layout, and ratings are identical to the base 3RV1011-0HA10. Same 45 mm width, same DIN-rail clip, same screw-terminal pattern — it's a drop-in replacement."},{"question":"What is the breaking capacity of 3RV1011-0HA10-ZX95 at 400 V?","answer":"Rated 100 kA at 400 V AC. Same rating holds at 240 V, 500 V, and 690 V."},{"question":"Where can I buy 3RV1011-0HA10-ZX95 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send the quantity for a firm price and lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0HA10-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0HA10-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}