{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0HA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0HA15","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0HA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0HA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1011-0HA15 motor protection circuit breaker, CLASS 10, 100 kA breaking capacity at 400 V, 45 mm wide, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"## Motor Protection Circuit Breaker for Panel Integration The Siemens 3RV1011-0HA15 is a SIRIUS motor protection circuit breaker with CLASS 10 trip, 100 kA breaking capacity at 400 V, and 45 mm width for DIN rail mounting. CLASS 10 is the standard trip class for general-purpose motors — pumps, fans, conveyors. It allows the motor to start and accelerate without nuisance tripping but clears fast enough on a locked rotor. For lower voltages, the 100 kA rating holds at 240 V and 500 V. The rated voltage range spans 20 to 690 V, covering common global motor voltages from 24 V control circuits up to 690 V industrial mains. ## DIN Rail and Clearance — Panel Fit Dimensions: 45 mm wide, 90 mm high, 75 mm deep. Clearance requirements: 20 mm upwards, 20 mm downwards, 9 mm at the side, 0 mm forwards, 0 mm backwards. That means no extra space is needed in front of or behind the breaker for arc venting — the 0 mm forwards/backwards clearance allows tight panel layouts. The M3 screw terminals for main contacts accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire. ## Switching Capacity and Fuse Coordination At AC-3 duty (motor switching), the maximum switching frequency is 15 operations per hour. For applications requiring higher cycling, consider a contactor for the switching duty and use this breaker only for protection. The breaker's rated operational current varies by voltage: 1 A at 24 V, 0.15 A at 60 V, 2 A at 110/120/125 V, 0.5 A at 230 V, and at 480 V it carries 0.8 A, at 600 V also 0.8 A. The 0.1 kW motor power rating at 230 V gives a rough sizing reference for small motor loads. ## Environmental Limits Storage and transport range: -50 to +80 °C.","metaTitle":"Siemens 3RV1011-0HA15 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV1011-0HA15 SIRIUS motor protection circuit breaker, CLASS 10 trip, 100 kA breaking capacity at 400 V. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Note":"1","Depth":"75 mm","Width":"45 mm","title":"3RV1011-0HA15","Height":"90 mm","Upwards":"20 mm","at 24 V":"1 A","at 60 V":"0.15 A","Forwards":"0 mm","at 110 V":"2 A","at 120 V":"2 A","at 125 V":"2 A","at 230 V":"0.5 A","at 240 V":"none required","at 400 V":"None required","at 500 V":"gL/gG 6 A","at 690 V":"gL/gG 6 A","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.55...0.8 A N-release 10 A Screw terminal Standard switching capacity with transverse auxiliary switch 1 NO+1 NC","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.8 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.8 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.8 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.8 A","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","Of The Auxiliary And Control Contacts":"M3","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Electrical Endurance (Switching Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","contact rating of auxiliary contacts according to UL":"C300 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.55 ... 0.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$43.21","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2922d9490d0ae3afb0ac57d01c7fba70.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=138319&mlfb=3RV1011-0HA15"},"ai":{"faq":[{"question":"Will 3RV1011-0HA15 fit a panel built for 3RV1011-0HA10?","answer":"The 3RV1011-0HA15 shares the same 45 mm width, 90 mm height, and 75 mm depth as the 3RV1011-0HA10. Both mount on 35 mm DIN rail and use M3 main contact terminals. The same clearance requirements apply (20 mm up/down, 9 mm side). Panel fit is identical — no rewiring or re-drilling needed for the swap."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0HA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0HA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}