{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-0HA20","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-0HA20","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-0HA20","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0HA20","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1011-0HA20, motor-protective circuit breaker, 0.8 A rated continuous current, Trip Class 10, 100 kA breaking capacity at 400 V AC, 3-pole, spring-loaded terminals, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"The Siemens 3RV1011-0HA20 is a SIRIUS motor-protective circuit breaker rated for 0.8 A continuous current with Trip Class 10 thermal overload protection. The 0.8 A rating corresponds to roughly 0.18 kW at 400 V three-phase, so this is sized for fractional-horsepower motors: small conveyors, fan drives, pump auxiliaries. The 45 mm width eats one standard DIN module; depth is 81 mm, height 90 mm. Zero clearance needed at the back or sides — no ventilation gap required, so it packs tight in a panel. Spring-loaded terminals on both main and auxiliary circuits accept 2x (0.25 to 2.5 mm²) solid or 2x (0.25 to 1.5 mm²) finely stranded with ferrule. AWG equivalent is 2x (24 to 14). The IP20 finger-safe front cover protects against accidental contact in an open panel. Rated short-circuit breaking capacity is 100 kA at 240 V, 400 V, 500 V, and 690 V AC — flat across the voltage band. That gives generous SCCR headroom for most industrial distribution panels; the breaker can clear a fault without upstream fuse assistance in high-fault installations. Power dissipation is 5.5 W total in hot operating state, or 1.8 W per pole. That matters for enclosure thermal rise calculations when grouping several breakers in a small cabinet. Shock resistance is 25 g for 11 ms. RoHS compliance date is 01.01.2013, covering the EU substance prohibitions. The auxiliary switch extension option is supported, so you can add a signal contact for remote status monitoring.","metaTitle":"Siemens 3RV1011-0HA20 SIRIUS Motor Circuit Breaker, 0.8 A, C","metaDescription":"Siemens 3RV1011-0HA20 SIRIUS motor-protective circuit breaker, 0.8 A rated current, Trip Class 10, 100 kA breaking capacity at 400 V. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"81 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"90 mm","Backwards":"0 mm","Trip Class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Shock Resistance":"25g / 11 ms","Mounting Position":"any","Product Brand Name":"SIRIUS","Product Designation":"circuit breaker","at 400 V rated value":"0.18 kW","Design Of The Product":"for motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"spring-loaded terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"5.5 W","Substance Prohibitance (Date)":"01.01.2013","Continuous Current Rated Value":"0.8 A","at AWG cables for main contacts":"2x (24 ... 14)","protection class IP on the front":"IP20","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 000 V","at AC in hot operating state per pole":"1.8 W","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Touch Protection Against Electrical Shock":"finger-safe","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","number of CO contacts for auxiliary contacts":"0","operational current at AC-3 at 400 V rated value":"0.8 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Design Of The Overcurrent Release And Short-Circuit Release":"thermomagnetic","Arrangement Of Electrical Connectors For Main Current Circuit":"front side","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Mechanical Service Life (Switching Cycles) Of The Main Contacts Typical":"100 000","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.55 ... 0.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=410314&mlfb=3RV1011-0HA20","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-0HA20/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-0HA20","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-0HA20 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}