{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-1AA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-1AA10","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-1AA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-1AA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1011-1AA10 motor protection circuit breaker, Trip Class 10, screw terminals, 100 kA breaking capacity at 400 V, for 35 mm DIN rail.","salesMarkdown":"## Motor protection breaker for panel integration Breaking capacity reaches 100 kA at 240 V, 400 V, and 500 V, dropping to 2 kA at 690 V. Any mounting position is permitted, which simplifies layout in a crowded enclosure. No ground-fault detection on this variant, so if that's required, a separate module or a different order code is needed. The depth is the critical dimension for enclosure depth clearance — 75 mm from the DIN rail face to the back of the breaker. Clearance requirements: 20 mm upward and downward, 9 mm to the side, 0 mm forward or backward — so you can butt it against the back panel or adjacent devices with zero gap. Main circuit terminals are M3 screw-type, accepting 2×(0.5…1.5 mm²) or 2×(0.75…2.5 mm²) solid or stranded wire. No special ferrules required for the stranded sizes within range. For back-up protection at 400 V, the manufacturer specifies a gL/gG 20 A fuse — this is the maximum fuse rating that preserves the breaker's interrupting rating.","metaTitle":"Siemens 3RV1011-1AA10 SIRIUS Motor Protection Breaker, 100 k","metaDescription":"Siemens 3RV1011-1AA10 SIRIUS motor protection circuit breaker, Trip Class 10, 100 kA breaking capacity at 400 V, screw terminals, DIN rail mount, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","title":"3RV1011-1AA10","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"none required","at 400 V":"gL/gG 20 A","at 500 V":"gL/gG 20 A","at 690 V":"gL/gG 20 A","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for motor protection, CLASS 10 A-release 1.1...1.6 A N-release 21 A Screw terminal Standard switching capacity","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 hp","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"1.6 A","at 500 V rated value":"100 kA","at 600 V rated value":"1.6 A","at 690 V rated value":"2 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at 460/480 V rated value":"1 hp","at 575/600 V rated value":"0.8 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"2 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"1.6 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","at AC-3e at 400 V rated value":"1.6 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"1.6 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","Electrical Endurance (Operating Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"21 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.1 ... 1.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$79.38","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/683dc5ca2e622735354ce2b4eda7019d.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=429861&mlfb=3RV1011-1AA10"},"ai":{"faq":[{"question":"What is the closest functional alternative — 3RV1011-1HA10?","answer":"The 3RV1011-1HA10 is a direct sibling in the same 3RV1011 series. The key difference is the auxiliary contact configuration: the -1AA10 carries no factory-fitted auxiliary contacts, while the -1HA10 includes one normally open and one normally closed auxiliary contact block. Panel fit, dimensions, and mounting are identical — you can swap one for the other without rewiring the main circuit, but you gain or lose the auxiliary signal contacts."},{"question":"What are the key ratings for this breaker?","answer":"Trip Class 10. Breaking capacity: 100 kA at 240 V, 400 V, and 500 V; 2 kA at 690 V. Phase failure detection is included. Rated operational voltage range is 20…690 V. Maximum switching frequency in AC-3 duty is 15 operations per hour."},{"question":"What compliance documentation is available for this part?","answer":"As a Siemens SIRUS product, the 3RV1011-1AA10 carries CE marking for the European market and is designed to meet IEC/EN 60947-2 and 60947-4-1 standards. UL and CSA approvals are typical for this series, though the specific listing for this order code should be verified against the nameplate or Siemens' declaration of conformity. RoHS and REACH compliance documentation is available from Siemens."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-1AA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-1AA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}