{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-1EA10-0FJ0-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-1EA10-0FJ0-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-1EA10-0FJ0-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-1EA10-0FJ0-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, motor-protective circuit breaker, 3RV1011-1EA10-0FJ0-ZX95, 4 A rated continuous current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw-type terminals, snap-on DIN-rail mount.","salesMarkdown":"The Siemens SIRIUS 3RV1011-1EA10-0FJ0-ZX95 is a motor-protective circuit breaker rated for 4 A continuous current. At 500 V AC the rating drops to 3 kA; at 690 V AC to 2 kA — a reminder that for 480 V or 600 V class systems the SCCR headroom narrows and coordination studies should confirm the let-through. No ground-fault detection on this variant, so any ground-leakage trip would need an external module or relay. The 45 mm width and 90 mm height keep it to a single 45 mm module — fits a standard panel slot without crowding adjacent breakers or contactors. Depth is 81 mm, so verify enclosure depth if back-panel wiring or busbars are tight. Mounting position is any, which helps when panels are oriented horizontally or on a swing frame. Terminals accept solid or stranded conductors: 2×(0.5…1.5 mm²) and 2×(0.75…2.5 mm²) per clamp, or 2× AWG 18…14 for the main contacts. Screw-type terminals — no spring-cage variant here; expect a screwdriver for termination.","metaTitle":"Siemens 3RV1011-1EA10-0FJ0-ZX95 SIRIUS Motor Circuit Breaker","metaDescription":"Siemens SIRIUS 3RV1011-1EA10-0FJ0-ZX95 motor-protective circuit breaker. 4 A continuous, 100 kA breaking capacity at 400 V AC, CLASS 10 trip. DIN-rail mount, phase failure detectio","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"81 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"45 mm","Height":"90 mm","Maximum":"2 000 m","Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Backwards":"0 mm","Trip class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","On The Front":"IP20","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","Auxiliary switch":"Yes","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Shock resistance":"25g / 11 ms","Mounting position":"any","Product brand name":"SIRIUS","Product designation":"circuit breaker","at 400 V rated value":"1.5 kW","Design of the product":"for motor protection","For Auxiliary Contacts":"0","Ground fault detection":"No","Phase failure detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"3 kA","at AC at 690 V rated value":"2 kA","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","Continuous current rated value":"4 A","at AWG conductors for main contacts":"2x (18 ... 14)","Surge voltage resistance rated value":"6 000 V","at AC in hot operating state per pole":"2.4 W","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","For Auxiliary And Control Current Circuit":"screw-type terminals","Removable Terminal For Auxiliary And Control Circuit":"No","Design of the overcurrent release and short-circuit release":"thermomagnetic","Arrangement of electrical connectors for main current circuit":"front side","Adjustable pick-up value current of the current-dependent overload release":"2.8 ... 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=90409&mlfb=3RV1011-1EA10-0FJ0-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-1EA10-0FJ0-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Does this breaker include phase failure protection?","answer":"Yes, phase failure detection is built in. It opens the circuit if one phase is lost, preventing single-phasing damage to motor windings. Ground fault detection is not included on this variant."},{"question":"Will 3RV1011-1EA10-0FJ0-ZX95 drop into a panel specified around 3RV1011-1HA10 without rewiring?","answer":"Both are 45 mm wide SIRIUS 3RV1 motor-protective breakers on the same DIN-rail footprint, so the mechanical fit is the same. However, the 1HA10 variant has a different current rating and trip setting. Verify the overload setting matches the motor FLA before swapping — the housing and terminal layout are identical, but the protection curve may differ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-1EA10-0FJ0-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-1EA10-0FJ0-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}