{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-1EA10-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-1EA10-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-1EA10-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-1EA10-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1011-1EA10-ZW96 motor protection circuit breaker, Class 10 trip, 100 kA breaking capacity at 400 V, phase failure detection, 45 mm wide, screw and snap-on 35 mm DIN rail mount.","salesMarkdown":"## Motor protection circuit breaker, Class 10, 100 kA At 45 mm wide and 75 mm deep, it fits standard motor starter combinations alongside contactors in the same rail footprint. The M3 screw terminals for the main circuit accept 2× (0.5…1.5 mm²) or 2× (0.75…2.5 mm²) solid or stranded wire. Clearance requirements: 20 mm upwards, 20 mm downwards, 9 mm at the side, 0 mm forwards and backwards. ## Key protection features No ground fault detection. The rated operational voltage range is 20…690 V. Operating temperature range -20…+60 °C, storage -50…+80 °C. Maximum switching frequency in AC-3 duty is 15 operations per hour. For short-circuit protection coordination, at 400 V use a gL/gG 40 A backup fuse; at 500 V and 690 V, gL/gG 35 A.","metaTitle":"Siemens 3RV1011-1EA10-ZW96 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV1011-1EA10-ZW96 SIRIUS motor protection circuit breaker, Class 10, 100 kA breaking capacity at 400 V, phase failure detection, DIN rail mount. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"none required","at 400 V":"gL/gG 40 A","at 500 V":"gL/gG 35 A","at 690 V":"gL/gG 35 A","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.33 hp","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"4 A","at 500 V rated value":"3 kA","at 600 V rated value":"4 A","at 690 V rated value":"2 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"0.13 hp","at 200/208 V rated value":"0.8 hp","at 220/230 V rated value":"0.75 hp","at 460/480 V rated value":"2 hp","at 575/600 V rated value":"3 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"3 kA","at AC at 690 V rated value":"2 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"4 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","at AC-3e at 400 V rated value":"4 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"4 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","Electrical Endurance (Operating Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"52 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.8 ... 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8b855e3a5100b7cd9f6bee1490d1e93a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=466118&mlfb=3RV1011-1EA10-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-1EA10-ZW96/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the 3RV1011-1EA10-ZW96 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the closest functional alternative to the 3RV1011-1EA10-ZW96?","answer":"The 3RV1011-1HA10 is a functional peer in the same SIRIUS motor protection breaker family. The -1EA10 variant carries a 100 kA breaking capacity at 400 V, while the -1HA10 typically covers a different current setting range. Verify the thermal setting range matches your motor FLA before substituting."},{"question":"Will the 3RV1011-1EA10-ZW96 drop into a panel specified for the 3RV1011-1HA10?","answer":"Yes, the 45 mm width, DIN rail mounting, and M3 screw terminals are identical across the SIRIUS 3RV1 family, so it fits the same panel cutout and wiring scheme. Only the current setting range and breaking capacity differ."},{"question":"What compliance documentation does Siemens provide for this part?","answer":"As a Siemens SIRIUS product, the 3RV1011-1EA10-ZW96 carries CE marking for the European market and is designed to IEC 60947-2 and IEC 60947-4-1 standards. RoHS and REACH declarations are available from Siemens documentation. UL and CSA listings are typical for this series but should be confirmed against the specific variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-1EA10-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-1EA10-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}