{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-1GA20-ZW98","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-1GA20-ZW98","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-1GA20-ZW98","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-1GA20-ZW98","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1011-1GA20-ZW98 motor protection circuit breaker, 6.3 A rated current, Trip Class 10, 100 kA breaking capacity at 240 V AC, 2.2 kW at 400 V AC, screw and snap-on DIN rail mount, spring-loaded terminals.","salesMarkdown":"## Motor Protection Circuit Breaker, 6.3 A, Trip Class 10 The Siemens SIRIUS 3RV1011-1GA20-ZW98 is a motor protection circuit breaker rated for 6.3 A continuous current, sized for a 2.2 kW motor at 400 V AC three-phase. Breaking capacity hits 100 kA at 240 V and 400 V AC, dropping to 3 kA at 500 V and 2 kA at 690 V. No ground-fault detection on this unit — that's handled separately if needed. Rated surge voltage 6 000 V, pollution degree typical for industrial control panels. Width is 45 mm — three 9 mm module spaces — so it fits standard distribution boards and motor starter assemblies. Any mounting position works; no derating needed for horizontal or inverted orientation. Accepts 2x (0.25 to 2.5 mm²) solid or 2x (0.25 to 1.5 mm²) finely stranded with ferrule. AWG equivalent 2x (24 to 14). Strip length and screwdriver size follow standard spring-clamp practice. IP20 on the front — finger-safe touch protection, but not washdown-rated. Shock rated 25 g for 11 ms — tough enough for machine-mounted applications near presses or conveyors. Power dissipation 7.25 W total at rated load, 2.4 W per pole.","metaTitle":"Siemens 3RV1011-1GA20-ZW98 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV1011-1GA20-ZW98 motor protection circuit breaker, 6.3 A continuous, Trip Class 10, 100 kA breaking at 240 V, 2.2 kW at 400 V. Active production, sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"81 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"90 mm","Backwards":"0 mm","Trip Class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Shock Resistance":"25g / 11 ms","Mounting Position":"any","Product Brand Name":"SIRIUS","Product Designation":"circuit breaker","at 400 V rated value":"2.2 kW","Design Of The Product":"for motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"spring-loaded terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"3 kA","at AC at 690 V rated value":"2 kA","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"7.25 W","Substance Prohibitance (Date)":"01.01.2013","Continuous Current Rated Value":"6.3 A","at AWG cables for main contacts":"2x (24 ... 14)","protection class IP on the front":"IP20","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 000 V","at AC in hot operating state per pole":"2.4 W","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Touch Protection Against Electrical Shock":"finger-safe","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","number of CO contacts for auxiliary contacts":"0","operational current at AC-3 at 400 V rated value":"6.3 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Design Of The Overcurrent Release And Short-Circuit Release":"thermomagnetic","Arrangement Of Electrical Connectors For Main Current Circuit":"front side","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Mechanical Service Life (Switching Cycles) Of The Main Contacts Typical":"100 000","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"4.5 ... 6.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=340463&mlfb=3RV1011-1GA20-ZW98","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-1GA20-ZW98/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV1011-1GA20-ZW98 and what is the lead time?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional alternative to 3RV1011-1GA20-ZW98?","answer":"The closest functional peer is 3RV1011-1HA10, which shares the same 6.3 A rating, Trip Class 10, and physical footprint. The -ZW98 suffix indicates a special version (often a customer-specific variant or customized marking); electrically and mechanically it drops into the same panel without rewiring."},{"question":"What compliance documentation does this breaker carry?","answer":"RoHS compliance is marked with a substance prohibition date of 01.01.2013. The SIRIUS series carries UL, CSA, and IEC certifications; specific approvals for this variant are confirmed at order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-1GA20-ZW98","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-1GA20-ZW98 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}