{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-1KA10-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-1KA10-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-1KA10-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-1KA10-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV1011-1KA10-ZW96, Trip Class 10, 13 kA at 400 V, phase failure detection, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"The Siemens 3RV1011-1KA10-ZW96 is a SIRIUS motor protection circuit breaker designed for motor protection, with Trip Class 10 and phase failure detection. It mounts via screw and snap-on onto 35 mm standard mounting rail per DIN EN 60715, fitting any mounting position. The 13 kA breaking capacity at 400 V gives it the headroom to clear a fault on a motor branch without cascading upstream — that's the number that decides selectivity in a panel coordination study. Panel integration is straightforward: screw and snap-on onto 35 mm DIN rail per DIN EN 60715. The 45 mm width and 75 mm depth mean it occupies a standard three-module footprint on the rail, leaving clearance of 20 mm upwards and downwards, 9 mm at the side, and zero forwards or backwards — so it fits tight against a back panel or enclosure wall. Main circuit connections use screw-type terminals accepting 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire.","metaTitle":"Siemens 3RV1011-1KA10-ZW96 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV1011-1KA10-ZW96 SIRIUS motor protection circuit breaker, Trip Class 10, 13 kA at 400 V, phase failure detection, screw and snap-on DIN rail mounting. Sourced to order ag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"gL/gG 80 A","at 400 V":"gL/gG 80 A","at 500 V":"gL/gG 50 A","at 690 V":"gL/gG 50 A","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"2 hp","at 240 V rated value":"100 kA","at 400 V rated value":"13 kA","at 480 V rated value":"12 A","at 500 V rated value":"3 kA","at 600 V rated value":"12 A","at 690 V rated value":"2 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at 110/120 V rated value":"0.5 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"8 hp","at 575/600 V rated value":"10 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"50 kA","at AC at 500 V rated value":"3 kA","at AC at 690 V rated value":"2 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"9.25 W","at AC-3 at 400 V rated value":"12.5 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"12.5 A","Design Of The Short-Circuit Trip":"magnetic","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"3.1 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","Electrical Endurance (Switching Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"156 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"9 ... 12.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3c0311df131fc6178ec6e0d2704b06c4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=393722&mlfb=3RV1011-1KA10-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-1KA10-ZW96/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3RV1011-1KA10-ZW96 and how is it quoted for volume purchases?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Volume pricing and lead time are confirmed at quote time."},{"question":"Will 3RV1011-1KA10-ZW96 drop into a panel that was specified around 3RV1011-1HA10 without rewiring?","answer":"Both are SIRIUS motor protection circuit breakers on the same 45 mm width footprint and DIN rail mount, so mechanical fit is identical. The 3RV1011-1KA10-ZW96 includes phase failure detection — verify whether the original 3RV1011-1HA10 had that feature; if not, the wiring and trip curve may differ."},{"question":"What compliance documentation does this brand provide for 3RV1011-1KA10-ZW96?","answer":"The Siemens SIRIUS series typically provides RoHS, REACH, UL, and IEC declarations. Specific documentation for this order code should be confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-1KA10-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-1KA10-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}