{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1011-1KA10-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1011-1KA10-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV1011-1KA10-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1011-1KA10-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1011-1KA10-ZW97, motor protection circuit breaker, Trip Class 10, screw and snap-on mounting onto 35 mm DIN rail, width 45 mm, depth 75 mm.","salesMarkdown":"Width is 45 mm, depth 75 mm, height 90 mm. Clearance requirements: 20 mm upwards, 20 mm downwards, 9 mm at the side, 0 mm forwards and backwards — so it can sit flush against the backplane and adjacent devices can be packed tightly side-by-side at 9 mm spacing. The part carries a product brand name of SIRIUS and is a circuit breaker design for motor protection.","metaTitle":"Siemens 3RV1011-1KA10-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV1011-1KA10-ZW97 SIRIUS motor protection circuit breaker, Trip Class 10, 45 mm wide, 75 mm deep. Phase failure detection, screw terminals, current lifecycle. Quoted to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"gL/gG 80 A","at 400 V":"gL/gG 80 A","at 500 V":"gL/gG 50 A","at 690 V":"gL/gG 50 A","Backwards":"0 mm","Downwards":"20 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"2 hp","at 240 V rated value":"100 kA","at 400 V rated value":"13 kA","at 480 V rated value":"12 A","at 500 V rated value":"3 kA","at 600 V rated value":"12 A","at 690 V rated value":"2 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"0.5 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"8 hp","at 575/600 V rated value":"10 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"50 kA","at AC at 500 V rated value":"3 kA","at AC at 690 V rated value":"2 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"9.25 W","at AC-3 at 400 V rated value":"12 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","at AC-3e at 400 V rated value":"12 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"12.5 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"3.1 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","Electrical Endurance (Operating Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"156 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"9 ... 12.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4b377bd1e295df8bd66b948b9527c177.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=68440&mlfb=3RV1011-1KA10-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1011-1KA10-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What is 3RV1011-1KA10-ZW97's listed depth (75 mm) on this component line?","answer":"The depth is 75 mm, with forwards clearance of 0 mm, so it sits flush against the backplane."},{"question":"What is 3RV1011-1KA10-ZW97's listed width (45 mm) on this component line?","answer":"Width is 45 mm, which is the standard single-module width for this SIRIUS frame size."},{"question":"Will 3RV1011-1KA10-ZW97 drop into a panel that was specified around 3RV1011-1HA10 without rewiring?","answer":"Yes, both share the same 45 mm width, 75 mm depth, DIN rail mounting, screw terminals, and clearance requirements, so mechanical fit is identical. Verify the rated current range and auxiliary contact arrangement on the specific 3RV1011-1HA10 variant before committing the BOM line."},{"question":"What compliance documentation does this brand provide for 3RV1011-1KA10-ZW97 (RoHS, REACH, UL, IEC)?","answer":"As a Siemens SIRIUS product, standard documentation includes RoHS and REACH declarations, and the part is designed to meet IEC/EN 60947-4-1 for motor protection. UL and CSA certifications are typical for the SIRIUS range; confirm the specific UL file number on the product label or request it via RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1011-1KA10-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1011-1KA10-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}