{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1021-0BA15-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1021-0BA15-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV1021-0BA15-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1021-0BA15-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV1021-0BA15-ZX95, 0.2 A continuous rated current, CLASS 10 trip class, 100 kA breaking capacity at 400 V AC, screw-type terminals, 45 mm width.","salesMarkdown":"## Breaking capacity and fault clearing This breaker carries a 100 kA rated short-circuit breaking capacity across the full voltage range: 240 V, 400 V, 500 V, and 690 V AC (–). Depth is 96 mm, height 97 mm — check the gland plate clearance if the panel is shallow. No side or backward spacing required, so you can pack modules tight. The main circuit accepts solid conductors: 2×(0.5…1.5 mm²) or 2×(0.75…2.5 mm²). Stranded: 2×(1…2.5 mm²) or 2×(2.5…6 mm²). AWG equivalent for the main contacts is 2×(14…10). The auxiliary switch is transverse design and the product extension auxiliary switch is available. Wire the load side to the motor contactor; the breaker's own auxiliary contacts can feed a PLC input for status feedback. Substance prohibitance date of 01.05.2012 aligns with RoHS compliance — the part is free of restricted substances per EU Directive 2011/65/EU. Shock resistance rated at 25 g for 11 ms. Mounting position is any, giving flexibility in panel layout.","metaTitle":"Siemens 3RV1021-0BA15-ZX95 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV1021-0BA15-ZX95 motor protection circuit breaker, 0.2 A continuous, CLASS 10 trip, 100 kA breaking capacity. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"45 mm","Height":"97 mm","at 24 V":"1 A","at 60 V":"0.15 A","Stranded":"2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)","at 230 V":"0.5 A","Backwards":"0 mm","Trip Class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Shock Resistance":"25g / 11 ms","Mounting Position":"any","Product Brand Name":"SIRIUS","Product Designation":"circuit breaker","at 400 V rated value":"0.06 kW","Design Of The Product":"for motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"5.5 W","Substance Prohibitance (Date)":"01.05.2012","Continuous Current Rated Value":"0.2 A","Design Of The Auxiliary Switch":"transverse","at AWG cables for main contacts":"2x (14 ... 10)","protection class IP on the front":"IP20","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 000 V","at AWG cables for auxiliary contacts":"2x (18 ... 14)","at AC in hot operating state per pole":"1.8 W","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Touch Protection Against Electrical Shock":"finger-safe","number of CO contacts for auxiliary contacts":"0","operational current at AC-3 at 400 V rated value":"0.2 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Design Of The Overcurrent Release And Short-Circuit Release":"thermomagnetic","Arrangement Of Electrical Connectors For Main Current Circuit":"front side","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Mechanical Service Life (Switching Cycles) Of The Main Contacts Typical":"100 000","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.14 ... 0.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=327791&mlfb=3RV1021-0BA15-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1021-0BA15-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the continuous current rating of 3RV1021-0BA15-ZX95?","answer":"The continuous rated current is 0.2 A. This is the current the breaker is set to protect at; it will trip on overload above this value per the CLASS 10 curve."},{"question":"What breaking capacity does 3RV1021-0BA15-ZX95 have at 400 V?","answer":"100 kA at 400 V AC. The same 100 kA rating holds at 240 V, 500 V, and 690 V AC."},{"question":"Will 3RV1021-0BA15-ZX95 drop into a panel specified for 3RV1011-0GA10?","answer":"Both are SIRIUS motor protection breakers on the same 45 mm DIN-rail footprint, so mechanical fit is the same. Verify the continuous current setting: 3RV1021-0BA15-ZX95 is 0.2 A; the 3RV1011-0GA10 may have a different range. Wire sizes and terminal types are identical screw-type terminals."},{"question":"Where can I buy 3RV1021-0BA15-ZX95 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ for volume or single-unit needs."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1021-0BA15-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1021-0BA15-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}