{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1021-1KA10-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1021-1KA10-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV1021-1KA10-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1021-1KA10-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1021-1KA10-ZW97, motor protection circuit breaker, 3-pole, 12.5 A rated continuous current, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, snap-on 35 mm DIN rail.","salesMarkdown":"The Siemens 3RV1021-1KA10-ZW97 is a SIRIUS motor protection circuit breaker, 3-pole, rated for 12.5 A continuous current and 5.5 kW at 400 V. No ground fault detection on this variant. ## Breaking capacity and where it fits Breaking capacity is 100 kA at both 240 V and 400 V AC, dropping to 42 kA at 500 V and 6 kA at 690 V. The 45 mm width means it takes up a single modular slot on the rail. ## Wiring and ratings at a glance Terminals accept solid or stranded wire: 2 conductors of 1 to 2.5 mm², or 2 conductors of 2.5 to 6 mm². For AWG, that's 2x 14-10 AWG. The depth is 96 mm, height 97 mm — fits standard shallow enclosures. Maximum operating frequency in AC-3 duty is 15 operations per hour — that's fine for a pump or conveyor starting a few times an hour, but not for a rapid-cycling application like a press or a crane.","metaTitle":"Siemens 3RV1021-1KA10-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV1021-1KA10-ZW97 SIRIUS motor protection circuit breaker, 12.5 A continuous, Class 10 trip, 100 kA at 400 V. Screw terminals, snap-on DIN rail. Current production. Quoted","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Solid":"2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)","Width":"45 mm","Height":"97 mm","Stranded":"2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)","Backwards":"0 mm","Trip Class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Shock Resistance":"25g / 11 ms","Mounting Position":"any","Product Brand Name":"SIRIUS","Product Designation":"circuit breaker","at 400 V rated value":"5.5 kW","Design Of The Product":"for motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"42 kA","at AC at 690 V rated value":"6 kA","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"9.25 W","Substance Prohibitance (Date)":"01.05.2012","Continuous Current Rated Value":"12.5 A","at AWG cables for main contacts":"2x (14 ... 10)","protection class IP on the front":"IP20","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 000 V","at AC in hot operating state per pole":"3.1 W","Finely Stranded With Core End Processing":"2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)","Number Of Poles For Main Current Circuit":"3","Touch Protection Against Electrical Shock":"finger-safe","number of CO contacts for auxiliary contacts":"0","operational current at AC-3 at 400 V rated value":"12.5 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Design Of The Overcurrent Release And Short-Circuit Release":"thermomagnetic","Arrangement Of Electrical Connectors For Main Current Circuit":"front side","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Mechanical Service Life (Switching Cycles) Of The Main Contacts Typical":"100 000","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"9 ... 12.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=303586&mlfb=3RV1021-1KA10-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1021-1KA10-ZW97/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV1021-1KA10-ZW97 and how do I get a price?","answer":"This part is sourced through independent distribution and quoted to order against an RFQ. Submit a request for current pricing and availability."},{"question":"Will 3RV1021-1KA10-ZW97 drop into a panel specified around 3RV6021-4DA10 without rewiring?","answer":"No — the 3RV6021-4DA10 is a different frame size with different terminal spacing and mounting footprint. The 3RV1021-1KA10-ZW97 is a 45 mm wide SIRIUS standard breaker; the 3RV6021-4DA10 is a wider compact breaker. Panel cutouts and wiring won't align directly."},{"question":"What compliance documentation does this brand provide for 3RV1021-1KA10-ZW97?","answer":"Siemens provides RoHS and REACH compliance documentation for this part, with a substance prohibitance date of 01.05.2012. The product carries IEC and UL certifications as standard for the SIRIUS line."},{"question":"What is the continuous current rating of this breaker?","answer":"Rated continuous current is 12.5 A, with a motor power rating of 5.5 kW at 400 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1021-1KA10-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1021-1KA10-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}