{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1021-4CA10-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1021-4CA10-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV1021-4CA10-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1021-4CA10-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV1021-4CA10-ZX95, 22 A rated current, 11 kW at 400 V, CLASS 10 trip, screw terminals, IP20 front.","salesMarkdown":"## Breaking capacity and fault handling Breaking capacity reaches 100 kA at 240 V AC, 50 kA at 400 V, 10 kA at 500 V, and 4 kA at 690 V. At the common 400 V line, 50 kA covers most industrial service-entrance fault levels without requiring an upstream current-limiting fuse — a real panel-space saver. Terminals accept 1 to 2.5 mm² solid or stranded (two wires per clamp) and 2.5 to 6 mm² (two wires). Shock-rated to 25g for 11 ms. RoHS compliant per the substance prohibition date of 01.05.2012.","metaTitle":"Siemens 3RV1021-4CA10-ZX95 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV1021-4CA10-ZX95 motor protection circuit breaker, 22 A continuous current, 11 kW at 400 V, CLASS 10 trip, 50 kA breaking capacity at 400 V. Active production, sou","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Solid":"2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)","Width":"45 mm","Height":"97 mm","Stranded":"2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)","Backwards":"0 mm","Trip Class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Shock Resistance":"25g / 11 ms","Mounting Position":"any","Product Brand Name":"SIRIUS","Product Designation":"circuit breaker","at 400 V rated value":"11 kW","Design Of The Product":"for motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"50 kA","at AC at 500 V rated value":"10 kA","at AC at 690 V rated value":"4 kA","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"10.5 W","Substance Prohibitance (Date)":"01.05.2012","Continuous Current Rated Value":"22 A","at AWG cables for main contacts":"2x (14 ... 10)","protection class IP on the front":"IP20","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 000 V","at AC in hot operating state per pole":"3.5 W","Finely Stranded With Core End Processing":"2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)","Number Of Poles For Main Current Circuit":"3","Touch Protection Against Electrical Shock":"finger-safe","number of CO contacts for auxiliary contacts":"0","operational current at AC-3 at 400 V rated value":"22 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Design Of The Overcurrent Release And Short-Circuit Release":"thermomagnetic","Arrangement Of Electrical Connectors For Main Current Circuit":"front side","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Mechanical Service Life (Switching Cycles) Of The Main Contacts Typical":"100 000","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"17 ... 22 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=295152&mlfb=3RV1021-4CA10-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1021-4CA10-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source for 3RV1021-4CA10-ZX95?","answer":"The 3RV6021-4DA10 is a peer in the SIRIUS family with a similar motor-protection role, but verify your specific current and breaking-capacity requirements — the ratings differ. We can source both and confirm fit against your BOM."},{"question":"What compliance documentation does this brand provide for 3RV1021-4CA10-ZX95?","answer":"RoHS compliant per the substance prohibition date of 01.05.2012. Standard documentation includes CE, UL, and CSA certifications — available on request with the RFQ."},{"question":"Where can I buy 3RV1021-4CA10-ZX95 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — no minimum order quantity restrictions."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1021-4CA10-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1021-4CA10-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}