{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1021-4DA15-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1021-4DA15-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV1021-4DA15-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1021-4DA15-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1021-4DA15-ZX95 motor protection circuit breaker, 25 A continuous rated current, CLASS 10 trip class, 11 kW at 400 V AC-3, screw-type terminals, snap-on DIN rail mount.","salesMarkdown":"## Motor protection circuit breaker, 25 A, CLASS 10 — SIRIUS 3RV1021-4DA15-ZX95 The Siemens SIRIUS 3RV1021-4DA15-ZX95 is a motor protection circuit breaker rated for 25 A continuous current with CLASS 10 trip characteristic, sized for 11 kW motor loads at 400 V AC-3 duty. Breaking capacity is 100 kA at 240 V AC, 50 kA at 400 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC — sufficient for most industrial panel fault levels downstream of a distribution transformer. The auxiliary switch is a transverse design and the product extension allows adding auxiliary contacts without removing the breaker from the rail. Any mounting position is permitted. Main circuit terminals accept solid conductors 2×(0.5…1.5 mm²) and 2×(0.75…2.5 mm²), or stranded 2×(1…2.5 mm²) and 2×(2.5…6 mm²). AWG equivalents for main contacts are 2×(14…10). Shock resistance rated at 25 g for 11 ms.","metaTitle":"Siemens 3RV1021-4DA15-ZX95 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV1021-4DA15-ZX95 motor protection circuit breaker, 25 A continuous, CLASS 10 trip, 11 kW at 400 V. Screw terminals, phase failure detection, DIN rail mount. Source","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"45 mm","Height":"97 mm","at 24 V":"1 A","at 60 V":"0.15 A","Stranded":"2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)","at 230 V":"0.5 A","Backwards":"0 mm","Trip Class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Shock Resistance":"25g / 11 ms","Mounting Position":"any","Product Brand Name":"SIRIUS","Product Designation":"circuit breaker","at 400 V rated value":"11 kW","Design Of The Product":"for motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"50 kA","at AC at 500 V rated value":"10 kA","at AC at 690 V rated value":"4 kA","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"10.5 W","Substance Prohibitance (Date)":"01.05.2012","Continuous Current Rated Value":"25 A","Design Of The Auxiliary Switch":"transverse","at AWG cables for main contacts":"2x (14 ... 10)","protection class IP on the front":"IP20","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 000 V","at AWG cables for auxiliary contacts":"2x (18 ... 14)","at AC in hot operating state per pole":"3.5 W","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Touch Protection Against Electrical Shock":"finger-safe","number of CO contacts for auxiliary contacts":"0","operational current at AC-3 at 400 V rated value":"25 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Design Of The Overcurrent Release And Short-Circuit Release":"thermomagnetic","Arrangement Of Electrical Connectors For Main Current Circuit":"front side","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Mechanical Service Life (Switching Cycles) Of The Main Contacts Typical":"100 000","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"20 ... 25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=928&mlfb=3RV1021-4DA15-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1021-4DA15-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV1021-4DA15-ZX95 and get a price?","answer":"This part is sourced and quoted to order through independent distribution against an RFQ. Submit a request for quote to confirm current pricing and availability."},{"question":"What is the breaking capacity of 3RV1021-4DA15-ZX95 at 400 V?","answer":"The breaking capacity is 50 kA at 400 V AC, 100 kA at 240 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC."},{"question":"What compliance documentation does Siemens provide for 3RV1021-4DA15-ZX95?","answer":"RoHS compliance is documented with a substance prohibition date of 01.05.2012. The part carries IP20 front protection and is designed to IEC/EN standards for motor protection circuit breakers."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1021-4DA15-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1021-4DA15-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}