{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1041-4JA10-ZW95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1041-4JA10-ZW95","canonicalUrl":"https://aoctrl.com/siemens/3RV1041-4JA10-ZW95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1041-4JA10-ZW95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1041-4JA10-ZW95 motor protection circuit breaker, 63 A continuous, 30 kW at 400 V, Class 10 trip, screw terminals, DIN rail mount.","salesMarkdown":"The Siemens 3RV1041-4JA10-ZW95 is a SIRIUS motor protection circuit breaker rated for 63 A continuous current and 30 kW at 400 V AC-3 duty, with a Class 10 trip characteristic. It is designed for motor protection in main current circuits, with screw-type box terminals for the main circuit and separate screw terminals for the auxiliary and control circuit. The 63 A continuous rating means this breaker handles motor full-load currents up to that level; the 30 kW at 400 V figure is the typical three-phase motor it protects. Breaking capacity is 100 kA at 240 V AC, 50 kA at 400 V AC, 12 kA at 500 V AC, and 6 kA at 690 V AC — sufficient for most industrial panel fault levels without cascading upstream. Any mounting position is allowed. Terminal capacity: solid conductors 2x (2.5 to 16 mm²); stranded 2x (10 to 50 mm²) or 1x (10 to 70 mm²). AWG equivalents for main contacts: 2x (10 to 1 AWG), 1x (10 to 2 AWG). Finely stranded with core-end processing: 2x (2.5 to 35 mm²) or 2.5 to 50 mm². No backwards or side clearance required. Power dissipation at rated current is 34 W total, 11.3 W per pole in hot operating state. Shock resistance is 25 g for 11 ms. Surge voltage resistance rated at 6000 V. Maximum operating frequency in AC-3 duty is 15 operations per hour.","metaTitle":"Siemens 3RV1041-4JA10-ZW95 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV1041-4JA10-ZW95 SIRIUS motor protection circuit breaker, 63 A continuous, 30 kW at 400 V, Class 10 trip. Screw terminals, DIN rail mount. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"174 mm","Solid":"2x (2.5 ... 16 mm²)","Width":"70 mm","Height":"165 mm","Stranded":"2x (10 ... 50 mm²), 1x (10 ... 70 mm²)","Backwards":"0 mm","Trip Class":"CLASS 10","At The Side":"0 mm","Rated Value":"690 V","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Shock Resistance":"25g / 11 ms","Mounting Position":"any","Product Brand Name":"SIRIUS","Product Designation":"circuit breaker","at 400 V rated value":"30 kW","Design Of The Product":"for motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals with box terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"50 kA","at AC at 500 V rated value":"12 kA","at AC at 690 V rated value":"6 kA","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"34 W","Substance Prohibitance (Date)":"07/01/2006","Continuous Current Rated Value":"63 A","at AWG cables for main contacts":"2x (10 ... 1), 1x (10 ... 2)","protection class IP on the front":"IP20","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 000 V","at AC in hot operating state per pole":"11.3 W","Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²), 2.5 ... 50 mm²","Number Of Poles For Main Current Circuit":"3","Touch Protection Against Electrical Shock":"finger-safe","number of CO contacts for auxiliary contacts":"0","operational current at AC-3 at 400 V rated value":"63 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Design Of The Overcurrent Release And Short-Circuit Release":"thermomagnetic","Arrangement Of Electrical Connectors For Main Current Circuit":"front side","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Mechanical Service Life (Switching Cycles) Of The Main Contacts Typical":"50 000","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"45 ... 63 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=90424&mlfb=3RV1041-4JA10-ZW95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1041-4JA10-ZW95/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source to 3RV1041-4JA10-ZW95?","answer":"The closest functional peer is the 3RV6021-4DA10, which is a similar SIRIUS motor protection circuit breaker. However, the 3RV1041-4JA10-ZW95 is the exact order code for this specific rating and terminal configuration — verify terminal size and trip class before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1041-4JA10-ZW95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1041-4JA10-ZW95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}