{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1353-6FP10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1353-6FP10","canonicalUrl":"https://aoctrl.com/siemens/3RV1353-6FP10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1353-6FP10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS molded-case circuit breaker, 3RV1353-6FP10, 5 A continuous, 85 kA breaking capacity at 400 V AC, 3-pole, screw terminals, IP20 front.","salesMarkdown":"Rated at 5 A continuous and delivering 5 A in AC-3 duty at 400 V, it handles motor loads up to 2.2 kW at 400 V. The breaking capacity is 85 kA at 400 V AC, dropping to 10 kA at 690 V — so at typical 400 V distribution, it clears high fault currents without upstream coordination issues. Mounts via screw fixing in any position, with IP20 finger-safe touch protection on the front. The 5 A AC-3 rating governs motor switching: it matches the inrush and breaking duty of a small motor starter combination. The 15 operations per hour maximum is a thermal limit for repetitive starting — fine for occasional cycling, not for high-speed jogging. Zero clearance required at the back and sides for heat dissipation, simplifying panel layout.","metaTitle":"Siemens 3RV1353-6FP10 SIRIUS MCCB, 5 A, 85 kA @ 400 V","metaDescription":"Siemens 3RV1353-6FP10 SIRIUS molded-case circuit breaker, 5 A continuous, 85 kA breaking capacity at 400 V AC. Screw terminals, IP20 front. Active production, sourced to order. Req","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"70 mm","Width":"90 mm","Height":"130 mm","Backwards":"0 mm","At The Side":"0 mm","Rated Value":"690 V","During Storage":"-40 ... +70 °C","lifecycle_stage":"current","During Operation":"-25 ... +70 °C","During Transport":"-40 ... +70 °C","Fastening Method":"screw fixing","Shock Resistance":"12g / 11 ms","Mounting Position":"any","Product Brand Name":"SIRIUS","Product Designation":"molded-case circuit breaker","at 400 V rated value":"2.2 kW","Design Of The Product":"for starter combinations","Ground Fault Detection":"No","Phase Failure Detection":"No","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"85 kA","at AC at 500 V rated value":"50 kA","at AC at 690 V rated value":"10 kA","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"08.01.2008","Continuous Current Rated Value":"5 A","protection class IP on the front":"IP20","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"8 000 V","Number Of Poles For Main Current Circuit":"3","Touch Protection Against Electrical Shock":"finger-safe","number of CO contacts for auxiliary contacts":"0","operational current at AC-3 at 400 V rated value":"5 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Design Of The Overcurrent Release And Short-Circuit Release":"magnetic","Arrangement Of Electrical Connectors For Main Current Circuit":"front side","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Mechanical Service Life (Switching Cycles) Of The Main Contacts Typical":"25 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=288013&mlfb=3RV1353-6FP10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1353-6FP10/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the 3RV1353-6FP10 at 400 V?","answer":"85 kA at 400 V AC. At 690 V it is 10 kA."},{"question":"Where can I buy the 3RV1353-6FP10?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"Does the 3RV1353-6FP10 include ground fault or phase failure detection?","answer":"No — ground fault detection and phase failure detection are both listed as 'No'. It is a basic magnetic-only MCCB for overcurrent and short-circuit protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1353-6FP10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1353-6FP10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}