{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1364-7CN10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1364-7CN10","canonicalUrl":"https://aoctrl.com/siemens/3RV1364-7CN10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1364-7CN10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS molded-case circuit breaker, 3RV1364-7CN10, 160 A, 200 kA at 400 V AC, 3-pole, screw terminals, IP20 front.","salesMarkdown":"Rated 160 A continuous with a 90 kW motor rating at 400 V, it clears faults up to 200 kA at 400 V AC, which puts it squarely into high-SCCR plant-floor distribution. That matters when the transformer feeding the panel is large enough to deliver that kind of bolted-fault current. The 160 A continuous current matches a 160 A bus or feeder; the 90 kW motor rating at 400 V tells you it can back a motor starter for a 90 kW load in AC-3 duty. The electronic short-circuit trip gives adjustable or fixed magnetic pickup curves — no thermal bimetal creep, so nuisance tripping on inrush is easier to dial out. Voltage range 20…690 V AC covers standard low-voltage networks from control power through 690 V industrial mains. Mounting position any, screw fixing, IP20 finger-safe front — install it in any orientation in a standard enclosure. The 103.5 mm depth keeps it shallow enough for shallow backpanels; the 105 mm width matches the SIRIUS 3RV form factor for uniform DIN-rail or screw-panel layouts.","metaTitle":"Siemens 3RV1364-7CN10 SIRIUS MCCB, 160 A, 200 kA at 400 V","metaDescription":"Siemens SIRIUS 3RV1364-7CN10 molded-case circuit breaker, 160 A continuous, 200 kA SCCR at 400 V AC, 90 kW motor rating. Active production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"103.5 mm","Width":"105 mm","Height":"205 mm","Backwards":"0 mm","At The Side":"0 mm","Rated Value":"20 ... 690 V","During Storage":"-40 ... +70 °C","lifecycle_stage":"current","During Operation":"-25 ... +70 °C","During Transport":"-40 ... +70 °C","Fastening Method":"screw fixing","Shock Resistance":"12g / 11 ms","Mounting Position":"any","Product Brand Name":"SIRIUS","Product Designation":"molded-case circuit breaker","at 400 V rated value":"90 kW","Design Of The Product":"for starter combinations","Ground Fault Detection":"No","Phase Failure Detection":"No","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"200 kA","at AC at 500 V rated value":"150 kA","at AC at 690 V rated value":"80 kA","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"01/08/2008","Continuous Current Rated Value":"160 A","Design Of The Short-Circuit Trip":"electronic","protection class IP on the front":"IP20","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"8 000 V","Number Of Poles For Main Current Circuit":"3","Touch Protection Against Electrical Shock":"finger-safe","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","operational current at AC-3 at 400 V rated value":"160 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Design Of The Overcurrent Release And Short-Circuit Release":"electronic","Arrangement Of Electrical Connectors For Main Current Circuit":"front side","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"1 600 A","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Mechanical Service Life (Operating Cycles) Of The Main Contacts Typical":"20 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=290004&mlfb=3RV1364-7CN10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1364-7CN10/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting rating at 400 V?","answer":"The 3RV1364-7CN10 clears faults up to 200 kA at 400 V AC."},{"question":"Where can I buy 3RV1364-7CN10?","answer":"This part is sourced to order against an RFQ through independent distribution — availability and pricing are confirmed at quote time."},{"question":"What compliance documentation does Siemens provide for 3RV1364-7CN10?","answer":"The evidence lists a substance prohibition date of 01/08/2008, indicating RoHS compliance. The part carries IP20 finger-safe touch protection on the front."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1364-7CN10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1364-7CN10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}