{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1364-7EN10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1364-7EN10","canonicalUrl":"https://aoctrl.com/siemens/3RV1364-7EN10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1364-7EN10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS molded-case circuit breaker for starter combinations, 3RV1364-7EN10, 250 A continuous, 200 kA SCCR at 400 V AC, 132 kW motor rating, screw terminals, IP20 front.","salesMarkdown":"Rated 250 A continuous with a 200 kA interrupting capacity at 400 V AC, it handles motor loads up to 132 kW at 400 V without breaking a sweat. The electronic short-circuit trip gives you precision coordination downstream, and the IP20 finger-safe front keeps the wireman safe during commissioning. That rating means this MCCB safely interrupts faults up to 200 kA without cascading upstream — critical when you're feeding a line with transformer capacity behind it. The 132 kW motor rating at 400 V gives you a direct sizing anchor: if your motor plate says 132 kW at 400 V, this breaker is the right match for AC-3 starting duty. Screw fixing to the mounting plate — no DIN rail on this frame size at 105 mm wide by 205 mm tall by 103.5 mm deep. The 0 mm clearance required at the back and sides means you can pack it tight against the gland plate or adjacent breakers without derating. Any mounting position works, so vertical bus bars or horizontal layouts are both fine. Substance prohibitance date of 01/08/2008 aligns with RoHS compliance — the part meets the EU RoHS directive effective from that date. No ground fault or phase failure detection built in (those functions live in the upstream protection or the motor management system), so plan your protection scheme accordingly.","metaTitle":"Siemens 3RV1364-7EN10 SIRIUS MCCB, 250 A, 200 kA at 400 V","metaDescription":"Siemens 3RV1364-7EN10 SIRIUS molded-case circuit breaker, 250 A continuous, 200 kA SCCR at 400 V AC, 132 kW motor rating. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"103.5 mm","Width":"105 mm","Height":"205 mm","Backwards":"0 mm","At The Side":"0 mm","Rated Value":"20 ... 690 V","During Storage":"-40 ... +70 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +70 °C","Fastening Method":"screw fixing","Shock Resistance":"12g / 11 ms","Mounting Position":"any","Product Brand Name":"SIRIUS","Product Designation":"molded-case circuit breaker","at 400 V rated value":"132 kW","Design Of The Product":"for starter combinations","Ground Fault Detection":"No","Phase Failure Detection":"No","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"200 kA","at AC at 500 V rated value":"150 kA","at AC at 690 V rated value":"80 kA","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"01/08/2008","Continuous Current Rated Value":"250 A","Design Of The Short-Circuit Trip":"electronic","protection class IP on the front":"IP20","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"8 000 V","Number Of Poles For Main Current Circuit":"3","Touch Protection Against Electrical Shock":"finger-safe","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","operational current at AC-3 at 400 V rated value":"250 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Design Of The Overcurrent Release And Short-Circuit Release":"electronic","Arrangement Of Electrical Connectors For Main Current Circuit":"front side","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"2 500 A","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Mechanical Service Life (Operating Cycles) Of The Main Contacts Typical":"20 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=535396&mlfb=3RV1364-7EN10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1364-7EN10/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV1364-7EN10?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the interrupting capacity of 3RV1364-7EN10 at 400 V?","answer":"200 kA at 400 V AC, which covers most distribution board fault levels without cascading upstream."},{"question":"What motor power does 3RV1364-7EN10 support at 400 V?","answer":"132 kW at 400 V AC, AC-3 duty — direct sizing for a 132 kW motor on a 400 V system."},{"question":"What are the mounting dimensions of 3RV1364-7EN10?","answer":"105 mm wide, 205 mm tall, 103.5 mm deep. Screw fixing, zero clearance required at back and sides."},{"question":"Does 3RV1364-7EN10 have ground fault or phase failure detection?","answer":"No — those functions are not built in; plan for upstream protection or a motor management system for phase loss and ground fault coverage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1364-7EN10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1364-7EN10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}