{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1611-0BD10-ZW98","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1611-0BD10-ZW98","canonicalUrl":"https://aoctrl.com/siemens/3RV1611-0BD10-ZW98","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1611-0BD10-ZW98","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV1611-0BD10-ZW98 circuit breaker for fuse monitoring, size S00, 100 kA breaking capacity at 400 V AC, screw terminals, phase failure detection.","salesMarkdown":"It's not a standard motor protection breaker; the design is for fuse monitoring. Rated operational voltage spans 20 to 690 V, and it delivers a 100 kA breaking capacity at 240 V, 400 V, 500 V, and 690 V AC — that's the kind of fault current you'd see on a large industrial distribution board, not a light commercial panel. It includes phase failure detection, so if one fuse blows on a three-phase line, the breaker sees the missing phase and opens — preventing single-phasing damage to motors or transformers downstream. No ground fault detection on this unit. Size S00 frame — that's the smallest SIRIUS frame, so it fits in tight DIN-rail enclosures. Any mounting position works. Clearances: 20 mm above and below, 9 mm to the side, zero forward or backward clearance needed. That zero forward clearance is handy when you're packing breakers tight against a gland plate. Screw terminals for the main circuit accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire, M3 screws on the main contacts. ## Operating conditions and ratings Operates at -20 to +60 °C; stores or ships at -50 to +80 °C. That -20 °C floor is fine for a heated electrical room but borderline for an unheated North Sea pump house — plan the enclosure heater accordingly. Maximum switching rate at AC-3 or AC-3e duty is 15 operations per hour. That's typical for a fuse-monitoring breaker that only operates on fault events, not a frequent switching device like a contactor. At 480 V and 600 V the rated current drops to 0.2 A — that's unusual and likely reflects the fuse-monitoring sense circuit, not the main path. The main breaking capacity stays at 100 kA across the voltage range up to 690 V (-).","metaTitle":"Siemens 3RV1611-0BD10-ZW98 SIRIUS Circuit Breaker, 100 kA, F","metaDescription":"Siemens 3RV1611-0BD10-ZW98 SIRIUS circuit breaker for fuse monitoring. 100 kA breaking capacity at 400 V AC, size S00, phase failure detection. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","Height":"90 mm","Upwards":"20 mm","Forwards":"0 mm","at 240 V":"none required","at 400 V":"None required","at 500 V":"None required","at 690 V":"None required","Backwards":"0 mm","Downwards":"20 mm","At The Side":"9 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.2 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.2 A","at 690 V rated value":"100 kA","Design Of The Product":"for fuse monitoring","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.2 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"01/01/2013","at AC-3e at 400 V rated value":"0.2 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.2 A","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"0","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"1.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=104896&mlfb=3RV1611-0BD10-ZW98","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV1611-0BD10-ZW98/alternatives.json"},"ai":{"faq":[{"question":"What is the 3RV1611-0BD10-ZW98 used for?","answer":"It's a circuit breaker designed for fuse monitoring — it detects a blown fuse and can trip or signal the fault, protecting downstream equipment from single-phasing. It includes phase failure detection."},{"question":"Will 3RV1611-0BD10-ZW98 drop into a panel specified around 3RV1011-0GA10?","answer":"Both are size S00 and mount on 35 mm DIN rail, so the footprint is the same. But the 3RV1611 is a fuse-monitoring breaker, while the 3RV1011 is a standard motor protection breaker — different internal trip characteristics. They are not drop-in replacements without checking the protection curve."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1611-0BD10-ZW98","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1611-0BD10-ZW98 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}