{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV1611-1CG14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV1611-1CG14","canonicalUrl":"https://aoctrl.com/siemens/3RV1611-1CG14","factsUrl":"https://aoctrl.com/api/mcp/products/3RV1611-1CG14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker, 3RV1611-1CG14, size S00, for distance protection, 100 kA breaking capacity at 240 V AC, 50 kA at 400 V AC, screw-type terminals, DIN rail mount.","salesMarkdown":"Rated operating voltage spans 20 to 690 V AC, with a 100 kA breaking capacity at 240 V AC and 50 kA at 400 V AC — that SCCR headroom means it safely interrupts bolted faults up to those levels without cascading upstream, critical for panel selectivity studies. Ground fault detection is not included — that's handled separately if your circuit requires GFCI. Mounting position is any, but the clearance zones are specified: 20 mm upwards and downwards, 9 mm at the side, 0 mm forwards and backwards. That side clearance is tight — adjacent breakers or terminals must leave at least 9 mm for air circulation and arc-quenching. Main circuit terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire, terminated with a Pozidriv size 2 screwdriver. For the control circuit at 24 V or 60 V, the auxiliary contact draws 0.3 A. At 240 V no external fuse is required; at 400 V the recommended backup fuse is gL/gG 35 A, stepping down to gL/gG 25 A at 500 V and 690 V. That fuse coordination protects the breaker's own short-circuit capacity.","metaTitle":"Siemens 3RV1611-1CG14 SIRIUS Circuit Breaker, 100 kA at 240","metaDescription":"Siemens 3RV1611-1CG14 SIRIUS circuit breaker for distance protection, size S00. 100 kA breaking capacity at 240 V AC, 50 kA at 400 V AC. Phase failure detection, DIN rail mount. So","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"75 mm","Width":"45 mm","title":"3RV1611-1CG14","Height":"90 mm","Upwards":"20 mm","at 24 V":"0.3 A","at 60 V":"0.3 A","Forwards":"0 mm","at 240 V":"none required","at 400 V":"gL/gG 35 A","at 500 V":"gL/gG 25 A","at 690 V":"gL/gG 25 A","Backwards":"0 mm","Downwards":"20 mm","At The Side":"9 mm","Rated Value":"20 ... 690 V","description":"Voltage transformer Circuit breaker, Size S00 2.5 A, N-release 10.5 A 1 CO with transverse auxiliary switch","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 240 V rated value":"100 kA","at 400 V rated value":"50 kA","at 480 V rated value":"2.5 A","at 600 V rated value":"2.5 A","Design Of The Product":"for distance protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"50 kA","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"400 V","Of The Main Contacts Typical":"10 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"2.5 A","at AC-3e rated value maximum":"400 V","Of Auxiliary Contacts Typical":"10 000","Substance Prohibitance (Date)":"01/01/2013","at AC-3e at 400 V rated value":"2.5 A","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"60 Hz","Operational Current Rated Value":"2.5 A","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Rocker switch","Surge Voltage Resistance Rated Value":"6 kV","Of The Auxiliary And Control Contacts":"M3","at AC in hot operating state per pole":"2.4 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"1","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"2A FF 250V/1.1kA","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"10.5 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$154.94","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ed60c36e9011b3cc9c047339f9ee7ea3.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=359361&mlfb=3RV1611-1CG14"},"ai":{"faq":[{"question":"What is the breaking capacity of 3RV1611-1CG14 at 400 V?","answer":"50 kA at 400 V AC. At 240 V AC it's 100 kA. These are the rated short-circuit breaking capacities for the main circuit."},{"question":"Where can I buy 3RV1611-1CG14?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."},{"question":"Does 3RV1611-1CG14 include phase failure protection?","answer":"Yes, phase failure detection is built in. Ground fault detection is not included."},{"question":"What is the width of 3RV1611-1CG14?","answer":"45 mm. The depth is 75 mm and height is 90 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV1611-1CG14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV1611-1CG14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}