{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0AA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0AA10","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0AA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0AA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2011-0AA10 motor protection circuit breaker, size S00, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, 45 mm wide.","salesMarkdown":"It's the thing you put ahead of a contactor to keep a pump or conveyor motor from cooking itself on an overload or taking out the whole panel on a short. In a plant with big transformers feeding a 400 V bus, that 100 kA rating means you don't need a current-limiting fuse upstream to protect this breaker. That's the same rail every panel builder uses — no special adapters. Width is 45 mm, depth is 97 mm. Mounting position is any — you can lay it sideways or upside down inside a tight cabinet and it'll still trip correctly. The clearance around it: 50 mm above and below, 30 mm to the side, nothing needed front or back. The screws take a Pozidriv size 2 tip, or a 5-6 mm diameter screwdriver shaft — common tools on any electrician's belt. ## Environmental and operating limits That -20 °C floor matters if this breaker lives in an unheated pump house in a northern winter — it'll still trip on overload at freezing temps. Rated voltage range is 20 to 690 V.","metaTitle":"Siemens 3RV2011-0AA10 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV2011-0AA10 SIRIUS motor protection circuit breaker, size S00, Class 10 trip, 100 kA breaking capacity at 400 V. Screw terminals, DIN rail mount. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","title":"3RV2011-0AA10","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.11...0.16 A N-release 2.1 A screw terminal Standard switching capacity","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.16 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.16 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.16 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.16 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.16 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"2.1 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.11 ... 0.16 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2c7bbe814fee4827d3fda4af19565663.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=262828&mlfb=3RV2011-0AA10"},"ai":{"faq":[{"question":"Will 3RV2011-0AA10 drop into a panel specified around 3RV1011-0GA10 without rewiring?","answer":"Physically, yes — both are size S00 with the same 45 mm width and snap onto 35 mm DIN rail. The 3RV2011-0AA10 uses screw terminals; the 3RV1011-0GA10 may use spring-cage or screw depending on the suffix. Check terminal type on your existing panel before swapping."},{"question":"What compliance documentation is available for 3RV2011-0AA10?","answer":"As a SIRIUS catalog product, Siemens provides CE, UL, CSA, and IEC declarations on request. RoHS and REACH compliance documentation is standard for current-production SIRIUS breakers."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0AA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0AA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}