{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0AA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0AA15","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0AA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0AA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2011-0AA15, motor protection circuit breaker, Trip Class 10, 100 kA interrupting capacity at 400 V AC, screw-type terminals, snap-on 35 mm DIN rail.","salesMarkdown":"## Motor protection circuit breaker for the cure recipe The Siemens SIRIUS 3RV2011-0AA15 is a motor protection circuit breaker designed to handle the heat and fault currents a tire-curing press environment can throw at it. Trip Class 10 means it clears overloads within 10 seconds at 7.2× rated current — fast enough to protect a motor winding before the insulation degrades, even when the ambient temperature around the press is pushing 60 °C. The 100 kA interrupting capacity at 400 V AC is the number that matters for SCCR coordination: it safely breaks a bolted fault without cascading upstream, so a single motor branch fault doesn't take down the whole press PLC cabinet. ## Snap-on DIN rail and panel fit Mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715. The 45 mm width and 97 mm depth mean it occupies one standard modular slot — no surprises when you're laying out a retrofit panel for an existing press line. Any mounting position is allowed, so you can orient it to clear the gland plate or a neighboring contactor. ## Phase failure detection and wiring Built-in phase failure detection is a hard requirement for three-phase motor protection: if one phase drops, the breaker trips before the motor single-phases and cooks. Main contacts use M3 screw terminals; the wire range accepts 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²). That covers standard motor feeder cables up to 2.5 mm² without needing an adapter.","metaTitle":"Siemens 3RV2011-0AA15 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV2011-0AA15 SIRIUS motor protection circuit breaker, Trip Class 10, 100 kA interrupting capacity at 400 V. Phase failure detection. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","title":"3RV2011-0AA15","Height":"97 mm","Upwards":"50 mm","at 24 V":"1 A","at 60 V":"0.15 A","Forwards":"0 mm","at 120 V":"0.5 A","at 125 V":"0.5 A","at 230 V":"0.5 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","description":"Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.11...0.16 A N-release 2.1 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.16 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.16 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.16 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.16 A","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.16 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Of The Auxiliary And Control Contacts":"M3","at AC in hot operating state per pole":"1.8 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","contact rating of auxiliary contacts according to UL":"C300 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"2.1 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.11 ... 0.16 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$34.29","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0437cd371802def56942a88f85aaf181.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=385967&mlfb=3RV2011-0AA15"},"ai":{"faq":[{"question":"Where can I buy 3RV2011-0AA15 and how do I get a price?","answer":"This part is sourced to order against an RFQ. Submit a quote request; availability and current pricing are confirmed at quote time through independent distribution channels."},{"question":"Will 3RV2011-0AA15 drop into a panel that was specified around 3RV2011-0AA10 without rewiring?","answer":"Yes — both are 45 mm wide, 97 mm deep, share the same SIRIUS footprint, and mount on 35 mm DIN rail. The terminal layout and wire range are identical, so no rewiring is needed for the swap."},{"question":"What compliance documentation does Siemens provide for 3RV2011-0AA15?","answer":"Siemens SIRIUS components typically carry UL, CSA, CE, and IEC certifications, plus RoHS and REACH compliance declarations. Specific certificate numbers are available upon request with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0AA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0AA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}