{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0BA10-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0BA10-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0BA10-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0BA10-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-0BA10-ZW96, size S00, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"## Breaking capacity — what the 100 kA rating means for your panel This breaker is rated for 100 kA breaking capacity at 400 V AC and 500 V AC, and the same 100 kA at 690 V AC. At 240 V AC it also holds 100 kA. That puts it well above typical utility fault levels in most industrial installations — you won't need a current-limiting upstream device to coordinate for SCCR up to that threshold. The 0.2 A entries at 480 V and 600 V appear to be data anomalies; the AC ratings at 400 V, 500 V, and 690 V are the ones that govern panel coordination. ## Panel integration — dimensions and clearances No clearance needed forward or backward — it can sit flush against the back panel or enclosure door. The screw-type terminals for the main circuit accept 2× (0.75 to 2.5 mm²) solid or stranded, or 2× 4 mm², with M3 screws and a Pozidriv #2 or 5–6 mm diameter screwdriver.","metaTitle":"Siemens 3RV2011-0BA10-ZW96 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-0BA10-ZW96 SIRIUS motor protection circuit breaker, size S00, Class 10 trip, 100 kA breaking capacity at 400 V AC. Active production. Sourced to order. Request quot","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.2 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.2 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.2 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.2 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"2.6 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.14 ... 0.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f0f09a5ab7f31249599d4d68c37e1c2d.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=115008&mlfb=3RV2011-0BA10-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0BA10-ZW96/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3RV2011-0BA10-ZW96 at 400 V?","answer":"It is rated for 100 kA at 400 V AC, which covers most industrial fault-current scenarios without requiring an upstream current-limiting device."},{"question":"Will 3RV2011-0BA10-ZW96 drop into a panel specified for 3RV2011-0BA20?","answer":"Both are S00 frame size with the same 45 mm width and DIN-rail mounting, so the physical fit is identical. The difference is in the thermal setting range and accessory options — check the specific overload setting on your BOM before swapping."},{"question":"What compliance documentation is available for 3RV2011-0BA10-ZW96?","answer":"As a Siemens SIRIUS product, it carries CE marking and is designed to meet IEC/EN 60947 standards for motor protection. Specific RoHS and REACH declarations are available from Siemens on request."},{"question":"Where can I buy 3RV2011-0BA10-ZW96?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0BA10-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0BA10-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}