{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0CA10-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0CA10-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0CA10-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0CA10-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-0CA10-ZW96, frame size S00, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw and snap-on DIN rail mount.","salesMarkdown":"The Siemens 3RV2011-0CA10-ZW96 is a SIRIUS motor-protection circuit breaker in frame size S00, designed to protect motor branch circuits against overload and short-circuit. Rated breaking capacity hits 100 kA at 400 V AC (and at 240 V, 500 V, and 690 V AC), which gives solid SCCR headroom for most industrial panel designs without needing a current-limiting upstream fuse. Clearance requirements are 50 mm above and below, 30 mm to the side, and zero forward or backward. That 45 mm width means it occupies one standard 45 mm module slot on the rail, leaving room for a contactor or overload relay alongside. Terminals accept 2x 0.75–2.5 mm² solid/stranded or 2x 4 mm², with M3 screw terminals for the main circuit. Screwdriver spec is a PZ2 tip, shaft diameter 5–6 mm. Strip and torque per the terminal markings — no special tooling needed.","metaTitle":"Siemens 3RV2011-0CA10-ZW96 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-0CA10-ZW96 SIRIUS motor protection circuit breaker, Class 10 trip, frame size S00, 100 kA SCCR at 400 V. Snap-on DIN rail mount. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.25 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.25 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.25 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.25 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"3.3 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.18 ... 0.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/29ff034a94d27af561512f38d518e19c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=319765&mlfb=3RV2011-0CA10-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0CA10-ZW96/alternatives.json"},"ai":{"faq":[{"question":"What is the 3RV2011-0CA10-ZW96 used for?","answer":"It is a motor-protection circuit breaker in the SIRIUS family, used to protect motor branch circuits against overload and short-circuit. It includes phase failure detection and a Class 10 trip curve suited for standard induction motors."},{"question":"What is the breaking capacity of this circuit breaker?","answer":"It is rated 100 kA at 400 V AC, and also at 240 V, 500 V, and 690 V AC, providing high SCCR for industrial panels."},{"question":"Where can I buy the 3RV2011-0CA10-ZW96?","answer":"This part is sourced and quoted to order through our independent distribution channel. Submit an RFQ for current availability and pricing."},{"question":"Will the 3RV2011-0CA10-ZW96 fit in a panel designed for the 3RV1011-0GA10?","answer":"Both are frame size S00 with the same 45 mm width and DIN-rail mounting, so the physical footprint is identical. The 3RV1011-0GA10 is a newer-generation SIRIUS 3RV1 series; the 3RV2011-0CA10-ZW96 is the earlier 3RV2 generation. Wiring and terminal layout are functionally equivalent, so panel fit should be direct without rewiring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0CA10-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0CA10-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}