{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0DA10-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0DA10-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0DA10-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0DA10-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-0DA10-ZW97, size S00, Trip Class 10, 100 kA breaking capacity at 400 V, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"## Motor protection circuit breaker for panel builders and MRO It's designed to protect motor circuits against overload, short circuit, and phase failure — the three faults that burn out windings and idle a line. That's fast enough to protect the motor but avoids nuisance tripping on startup inrush. That's high enough for most industrial panel secondary distribution. The 45 mm width fits one standard modular slot — easy to swap into an existing panel without re-drilling the backplate. That's tight for a 100 kA device. Terminals accept 2x (0.75 to 2.5 mm²) solid/stranded or 2x 4 mm² — sized for standard motor circuit wiring. Screw terminals with M3 main contact screws; use a Pozidriv size 2 tip with a 5–6 mm shaft diameter. Storage and transport range -50 to +80 °C — fine for unheated warehouses or truck shipments in winter. Rated switching frequency at AC-3 and AC-3e is 15 operations per hour maximum — that's a motor start every 4 minutes. Not for high-cycle jogging or reversing service; that would need a contactor rated for higher mechanical life. ## Why the ratings matter for your BOM If one phase drops on a three-phase motor, the breaker trips before single-phasing cooks the winding. Ground fault detection is not included, so pair with a ground-fault relay if your installation requires it. The 100 kA breaking capacity at 240 V, 400 V, 500 V, and 690 V AC covers the common industrial voltages across North America and Europe. At 480 V and 600 V the rated current drops to 0.32 A — that's the thermal setting range, not the short-circuit rating.","metaTitle":"Siemens 3RV2011-0DA10-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-0DA10-ZW97 SIRIUS motor protection circuit breaker, size S00, Trip Class 10, 100 kA breaking capacity at 400 V. Screw and snap-on DIN rail mount. Current production","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.32 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.32 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.32 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.32 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.32 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (18 ... 14), 2x 12","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"4.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.22 ... 0.32 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=571868&mlfb=3RV2011-0DA10-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0DA10-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RV2011-0DA10-ZW97?","answer":"The depth is 97 mm. Overall dimensions are 97 mm deep × 45 mm wide × 97 mm tall."},{"question":"Will 3RV2011-0DA10-ZW97 drop into a panel specified around 3RV1011-0GA10?","answer":"Both are size S00 motor protection circuit breakers on 35 mm DIN rail, so the footprint and mounting are the same. The 3RV2011-0DA10-ZW97 is a current-production SIRIUS model; the 3RV1011-0GA10 is an earlier generation. Check the thermal setting range and auxiliary contact configuration against your BOM — the -ZW97 suffix may carry a customer-specific variant that differs from the standard 3RV1011-0GA10."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0DA10-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0DA10-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}