{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0DA10-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0DA10-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0DA10-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0DA10-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-0DA10-ZX95, size S00, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw and snap-on DIN rail mounting.","salesMarkdown":"## Motor protection circuit breaker, size S00, Trip Class 10 The Siemens 3RV2011-0DA10-ZX95 is a SIRIUS motor protection circuit breaker in the size S00 frame, Trip Class 10. Breaking capacity is 100 kA at 400 V AC, which covers most industrial distribution panels with high fault-current potential. The unit includes phase failure detection, so a lost phase on the line side will trip the breaker and prevent single-phasing damage to the motor. Mounting is via screw fixing or snap-on onto a 35 mm DIN rail per EN 60715, and the mounting position is any orientation — useful for tight enclosures where vertical or horizontal rail placement is required. ## Panel integration and wiring The breaker occupies a 45 mm width on the DIN rail, with a depth of 97 mm. Clearance requirements: 50 mm above and below, 30 mm at the sides, and no space forward or backward. Main circuit terminals accept screw-type connections: 2× (0.75 to 2.5 mm²) solid or stranded, or 2× 4 mm². The screwdriver shaft diameter is 5 to 6 mm, Pozidriv size 2 tip — a common panel-building tool. Terminal screws are M3. Ambient operating range is -20 to +60 °C with temperature compensation active across that span, so derating is not required within those limits. Storage and transport range extends to -50 to +80 °C.","metaTitle":"Siemens 3RV2011-0DA10-ZX95 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-0DA10-ZX95 SIRIUS motor protection circuit breaker, size S00, Trip Class 10, 100 kA breaking capacity at 400 V. Current lifecycle stage. Available to order against","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.32 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.32 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.32 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.32 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"4.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.22 ... 0.32 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/000d67398027c3ba52e78aca3f04fbf4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=62499&mlfb=3RV2011-0DA10-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0DA10-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Will 3RV2011-0DA10-ZX95 drop into a panel that was specified around 3RV2011-0AA10 without rewiring?","answer":"Yes, both share the same size S00 frame, 45 mm width, and DIN-rail mounting — the -ZX95 is a special variant of the -0AA10 with identical footprint and terminal layout."},{"question":"Does this circuit breaker include phase failure protection?","answer":"Yes, phase failure detection is built in — the breaker will trip on a lost phase to prevent single-phasing motor damage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0DA10-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0DA10-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}