{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0FA10-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0FA10-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0FA10-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0FA10-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-0FA10-ZW97, Size S00, Trip Class 10, 100 kA SCCR at 400 V AC, screw-type terminals, 45 mm wide, DIN rail mount.","salesMarkdown":"The Siemens SIRIUS 3RV2011-0FA10-ZW97 is a motor protection circuit breaker in Size S00 — the compact frame of the SIRIUS family, designed to snap onto a 35 mm DIN rail per DIN EN 60715 and fit into a control panel with a 45 mm width footprint. The operating temperature range of -20 to +60 °C covers most indoor panel environments, and the rated voltage span of 20 to 690 V means it handles everything from 24 V control circuits up to 690 V line feeds. The breaker needs 50 mm clearance upward and downward, 30 mm to the side, and zero forward or backward — so you can pack it tight against the backplane or a busbar cover as long as the vertical breathing space is respected. Screw-type terminals on the main circuit accept 2x (0.75 to 2.5 mm²) solid or stranded, or 2x 4 mm² — enough for the motor branch circuit wiring typical of a Size S00 breaker.","metaTitle":"Siemens 3RV2011-0FA10-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV2011-0FA10-ZW97 motor protection circuit breaker, Size S00, Trip Class 10, 100 kA SCCR at 400 V, screw-type terminals, DIN rail mount. Sourced to order against RF","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","at 690 V":"gL/gG 4 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.5 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.5 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.5 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.5 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.5 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (18 ... 14), 2x 12","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"6.5 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.35 ... 0.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a7b60d49439940beed2c2e462c1f7bac.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=571870&mlfb=3RV2011-0FA10-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0FA10-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source for 3RV2011-0FA10-ZW97?","answer":"The 3RV2011-0AA10 is a Size S00 motor protection breaker from the same SIRIUS family, but it carries different trip settings and auxiliary configurations — verify the overload range and terminal layout before substituting into an existing panel."},{"question":"What is the SCCR of 3RV2011-0FA10-ZW97 at 400 V?","answer":"100 kA at 400 V AC, which is the same rating at 240 V, 500 V, and 690 V — a flat 100 kA across the common industrial voltages."},{"question":"Will 3RV2011-0FA10-ZW97 drop into a panel specified for 3RV2011-0AA10 without rewiring?","answer":"Both are Size S00 with the same 45 mm width and DIN rail mounting, so the mechanical fit is identical. The terminal layout and screw-type connections are the same, but the trip class and phase failure detection differ — the -0FA10 variant includes phase failure detection and Trip Class 10, which the -0AA10 may not share."},{"question":"Where can I buy 3RV2011-0FA10-ZW97?","answer":"Sourced and quoted to order through independent distribution against an RFQ. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0FA10-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0FA10-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}