{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0FA10-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0FA10-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0FA10-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0FA10-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, size S00, 3RV2011-0FA10-ZX95, Trip Class 10, 100 kA SCCR at 400 V AC, screw-type terminals, DIN rail mount.","salesMarkdown":"## Motor protection circuit breaker, size S00 — Trip Class 10, 100 kA SCCR The interrupting rating is 100 kA at 240 V, 400 V, 500 V, and 690 V AC — that's a single symmetrical rating across the common industrial voltage bands, so no coordination derating is needed when the panel feeds multiple voltage levels. The screw-type terminals on the main circuit accept 2×(0.75–2.5 mm²) or a single 4 mm² conductor — sized for standard motor branch-circuit wiring up to the S00 frame limit. The 3RV2011-0FA10-ZX95 measures 45 mm wide × 97 mm high × 97 mm deep. Clearance requirements: 50 mm upwards and downwards, 30 mm to the side, 0 mm forwards and backwards. The zero forward clearance means the breaker can be mounted directly against the enclosure back wall or a busbar shield without additional spacing. The -20 °C floor matters for unheated enclosures in cold climates — the thermal trip curve stays compensated down to that point.","metaTitle":"Siemens 3RV2011-0FA10-ZX95 SIRIUS Motor Protection CB, Class","metaDescription":"Siemens 3RV2011-0FA10-ZX95 SIRIUS motor protection circuit breaker, size S00, Trip Class 10, 100 kA SCCR at 400 V AC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","at 690 V":"gL/gG 4 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.5 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.5 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.5 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.5 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"6.5 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.35 ... 0.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c387e01aefeb57c61b8525f16ea04d0f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=359717&mlfb=3RV2011-0FA10-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0FA10-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV2011-0FA10-ZX95?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"What is the interrupting rating of 3RV2011-0FA10-ZX95?","answer":"The interrupting rating is 100 kA at 240 V, 400 V, 500 V, and 690 V AC. This single symmetrical rating applies across the common industrial voltage bands, simplifying coordination studies."},{"question":"Will 3RV2011-0FA10-ZX95 drop into a panel specified around 3RV1011-0GA10?","answer":"Both are size S00 frame breakers with the same 45 mm width and DIN rail mounting, so the mechanical fit is identical. However, the 3RV2011-0FA10-ZX95 is a motor protection breaker with Trip Class 10 and phase failure detection, while the 3RV1011-0GA10 is a different variant — verify the trip curve and auxiliary contact configuration against your BOM before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0FA10-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0FA10-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}