{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0GA10-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0GA10-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0GA10-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0GA10-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, size S00, Trip Class 10, 100 kA SCCR at 400 V AC, screw-type terminals, 3RV2011-0GA10-ZW97.","salesMarkdown":"The S00 frame keeps the panel footprint tight — 45 mm wide — and the screw-type terminals accept 2×(0.75…2.5 mm²) solid or stranded, or 2×4 mm², with an M3 screw for the main contacts. The breaker includes phase failure detection, which is critical for three-phase motor protection — if one phase drops out, the motor draws higher current on the remaining phases, and this device will trip before winding damage occurs. Ground fault detection is not built in, so a separate ground-fault relay or RCD is needed if that protection is required. Temperature compensation is active across the -20 to +60 °C operating range, so the thermal trip curve stays accurate regardless of ambient temperature swings inside the enclosure. The storage and transport range extends from -50 to +80 °C. The maximum switching rate at AC-3 duty is 15 operations per hour, which suits motor starting applications but is not intended for high-cycle jogging or inching duty. The gL/gG fuse backup at 690 V is rated 6 A, providing additional short-circuit protection coordination where needed. Clearance requirements: 50 mm upwards and downwards, 30 mm at the sides, and 0 mm forwards and backwards. This means the breaker can be mounted flush against a backplate or enclosure wall at the rear, but needs breathing space above and below for arc-quenching and thermal dissipation. The screwdriver shaft diameter required is 5 to 6 mm for the terminal screws.","metaTitle":"Siemens 3RV2011-0GA10-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-0GA10-ZW97 SIRIUS motor protection circuit breaker, size S00, Trip Class 10, 100 kA SCCR at 400 V AC. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Trip Class":"CLASS 10","Product Status":"Active","Temp Operating Max":"60 °C","Temp Operating Min":"-20 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0efe2c89077f3a83742a8b8f90b38b17.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=165807&mlfb=3RV2011-0GA10-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0GA10-ZW97/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0GA10-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0GA10-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}