{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0GA25-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0GA25-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0GA25-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0GA25-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-0GA25-ZW97, Trip Class 10, 100 kA breaking capacity at 400 V AC, spring-loaded terminals, phase failure detection, 45 mm width, 97 mm depth.","salesMarkdown":"## Motor protection circuit breaker, SIRIUS, 3RV2011-0GA25-ZW97 The unit provides phase failure detection, so a lost phase on the line side will cause a trip, preventing single-phasing damage to the motor. The main circuit connections use spring-loaded terminals (cage clamp), accepting 2× (0.5... 2.5 mm²) solid or stranded conductors — no screw torque to verify, which speeds panel wiring. ## Integration notes The spring-loaded terminals accept 2× (0.5... 2.5 mm²) conductors — strip length per manufacturer recommendation for cage-clamp terminations. The unit occupies 45 mm of DIN rail width; with the required 50 mm clearance above and below, plan for roughly 145 mm of vertical panel space per breaker row. The temperature compensation is active across the full operating range, so the thermal trip curve stays accurate in warm enclosures.","metaTitle":"Siemens 3RV2011-0GA25-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-0GA25-ZW97 SIRIUS motor protection circuit breaker, Trip Class 10, 100 kA breaking capacity at 400 V, spring-loaded terminals, phase failure detection. Sourced to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"106 mm","Upwards":"50 mm","at 24 V":"1 A","at 60 V":"0.15 A","Forwards":"0 mm","at 120 V":"0.5 A","at 125 V":"0.5 A","at 230 V":"0.5 A","at 690 V":"gL/gG 6 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.63 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.63 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 3 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"3,0 x 0,5 mm","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.63 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.63 A","at AWG cables for main contacts":"2x (20 ... 12)","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"spring-loaded terminals","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 14)","at AC in hot operating state per pole":"1.8 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","Finely Stranded Without Core End Processing":"2x (0.5 ... 1.5 mm²)","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","contact rating of auxiliary contacts according to UL":"C300 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"8.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.45 ... 0.63 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d3b8f689e4d7f4c412046de455de23ca.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=622679&mlfb=3RV2011-0GA25-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0GA25-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the 3RV2011-0GA25-ZW97 at 400 V?","answer":"The breaking capacity is 100 kA at 400 V AC, which is sufficient for most industrial panelboard applications up to the service entrance."},{"question":"What type of terminals does the 3RV2011-0GA25-ZW97 use?","answer":"It uses spring-loaded terminals (cage clamp) for the main current circuit, accepting 2× (0.5... 2.5 mm²) solid or stranded conductors."},{"question":"Does the 3RV2011-0GA25-ZW97 detect phase failure?","answer":"Yes, it includes phase failure detection, which will trip the breaker if one phase is lost, protecting the motor from single-phasing damage."},{"question":"Where can I buy the 3RV2011-0GA25-ZW97?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and delivery estimate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0GA25-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0GA25-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}