{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0GA40","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0GA40","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0GA40","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0GA40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, size S00, 3RV2011-0GA40, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"The Siemens 3RV2011-0GA40 is a SIRIUS motor protection circuit breaker in size S00, designed for motor protection with phase failure detection and Trip Class 10. It mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, in any position, and fits a panel cutout that clears 50 mm above and below, 30 mm to the side, with zero clearance forward or backward. ## Breaking capacity and motor protection Rated breaking capacity hits 100 kA at 400 V AC and 690 V AC, meaning it can safely interrupt fault currents up to that level without upstream cascading — a key figure for panel SCCR coordination. Main circuit connections use ring cable lug with M3 screws. The S00 frame (45 mm wide, 97 mm deep) fits standard panel spacing. Ambient operating range -20 to +60 °C; storage and transport -50 to +80 °C.","metaTitle":"Siemens 3RV2011-0GA40 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV2011-0GA40 SIRIUS motor protection circuit breaker, size S00, 100 kA breaking capacity at 400 V, Trip Class 10. Available to order; RFQ for pricing and stock.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","at 690 V":"gL/gG 6 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.63 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.63 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"Ring cable lug connection","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"size 2 and Pozidriv 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"5.5 W","at AC-3 at 400 V rated value":"0.63 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.63 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.63 A","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"ring terminal lug connection","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","For Main Contacts For Ring Cable Lug":"0.8 ... 1.2 N·m","Surge Voltage Resistance Rated Value":"6 kV","Of The Auxiliary And Control Contacts":"M3","at AC in hot operating state per pole":"1.8 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","For Auxiliary Contacts For Ring Cable Lug":"1.2 ... 0.8 N·m","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Outer Diameter Of The Usable Ring Cable Lug Maximum":"7.5 mm","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"8.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.45 ... 0.63 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/755161271435bd8f3ba1e08fd2df6d40.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=119280&mlfb=3RV2011-0GA40","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0GA40/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV2011-0GA40 and how do I get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability; stock and lead time are confirmed at quote time."},{"question":"What is the breaking capacity of 3RV2011-0GA40 at 400 V?","answer":"The breaking capacity is 100 kA at 400 V AC, which is also the rating at 690 V AC — a high interrupt rating that supports panel SCCR coordination."},{"question":"What are the mounting dimensions for 3RV2011-0GA40?","answer":"Width is 45 mm, depth 97 mm, height 97 mm. Clearance required: 50 mm above and below, 30 mm to the side, zero forward or backward. Mounts on 35 mm DIN rail per DIN EN 60715 in any position."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0GA40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0GA40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}