{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0HA15-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0HA15-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0HA15-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0HA15-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor-protection circuit breaker, 3RV2011-0HA15-ZW97, Class 10 trip, 100 kA breaking capacity at 400 V, 45 mm wide, screw/snap-on mounting.","salesMarkdown":"The Siemens SIRIUS 3RV2011-0HA15-ZW97 is a motor-protection circuit breaker designed for Class 10 trip characteristics, with a rated breaking capacity of 100 kA at 400 V, 500 V, and 690 V. Compared to the base 3RV2011-0AA10 (which lacks the -ZW97 suffix and typically carries a lower breaking capacity or different auxiliary configuration), this -ZW97 variant retains the same 45 mm footprint and screw/snap-on rail mount but adds the full 100 kA SCCR at 400 V. The screw-type terminals for the main current circuit accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire, with M3 screws. Any mounting position is allowed, and the 97 mm depth leaves enough clearance behind a standard 120 mm deep enclosure. Temperature compensation is active from -20 to +60 °C, so the thermal trip curve stays accurate across that range.","metaTitle":"Siemens 3RV2011-0HA15-ZW97 SIRIUS Motor-Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV2011-0HA15-ZW97 motor-protection circuit breaker, Class 10 trip, 100 kA breaking capacity at 400 V, 45 mm wide, screw/snap-on DIN rail. Sourced to order against R","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","at 24 V":"1 A","at 60 V":"0.15 A","Forwards":"0 mm","at 120 V":"0.5 A","at 125 V":"0.5 A","at 230 V":"0.5 A","at 690 V":"gL/gG 6 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.8 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.8 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"0.8 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.8 A","at AWG cables for main contacts":"2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Of The Auxiliary And Control Contacts":"M3","at AC in hot operating state per pole":"2.4 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"100 000","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","contact rating of auxiliary contacts according to UL":"C300 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.55 ... 0.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d7765a153e8b76eb3dc0d74c90e35ad3.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=211734&mlfb=3RV2011-0HA15-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0HA15-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3RV2011-0HA15-ZW97?","answer":"It has a rated breaking capacity of 100 kA at 400 V, 500 V, and 690 V, making it suitable for high-fault-capacity industrial panels."},{"question":"Will 3RV2011-0HA15-ZW97 drop into a panel specified around 3RV2011-0AA10 without rewiring?","answer":"Yes, both share the same 45 mm width, DIN-rail mounting, and screw-type terminal pattern, so mechanical fit and wiring are identical. The key difference is the higher breaking capacity on the -ZW97 variant."},{"question":"Where can I buy 3RV2011-0HA15-ZW97?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0HA15-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0HA15-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}