{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0HA20","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0HA20","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0HA20","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0HA20","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-0HA20, Size S00, Trip Class 10, 100 kA breaking capacity at 400 V AC, screw and snap-on DIN rail mounting.","salesMarkdown":"## Motor protection circuit breaker — SIRIUS 3RV2011-0HA20 The Siemens 3RV2011-0HA20 is a SIRIUS motor protection circuit breaker, designed for motor protection with phase failure detection. It carries a Trip Class 10, meaning it will trip within 10 seconds at 7.2× the thermal setting — the standard for protecting standard induction motors against locked-rotor conditions without nuisance tripping on startup inrush. Breaking capacity is 100 kA at 400 V AC, which means it can safely interrupt a fault current up to that level without upstream fuses or breakers needing to clear the fault first — useful for high-fault panels where you want full selectivity downstream. Mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715, in any orientation. Size S00 keeps the footprint compact: 45 mm wide, 97 mm deep, 106 mm tall. Spring-loaded terminals on the main circuit accept 2× (0.5–4 mm²) solid or stranded.","metaTitle":"Siemens 3RV2011-0HA20 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV2011-0HA20 SIRIUS motor protection circuit breaker, Size S00, Trip Class 10, 100 kA breaking capacity at 400 V, screw and snap-on DIN rail mounting. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"106 mm","Upwards":"50 mm","Forwards":"0 mm","at 690 V":"gL/gG 6 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","Mounting Position":"any","Solid Or Stranded":"2x (0,5 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.1 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"0.8 A","at 500 V rated value":"100 kA","at 600 V rated value":"0.8 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"spring-loaded terminals","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 3 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"3,0 x 0,5 mm","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"0.8 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.8 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.8 A","at AWG cables for main contacts":"2x (20 ... 12)","Design Of The Short-Circuit Trip":"magnetic","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.55 ... 0.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d6a58e1aabd6fed8ff31b9d421675f90.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=271540&mlfb=3RV2011-0HA20","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0HA20/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RV2011-0HA20?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time; the part is sourced to order through independent distribution."},{"question":"What is 3RV2011-0HA20's listed depth?","answer":"97 mm."},{"question":"What is 3RV2011-0HA20's listed width?","answer":"45 mm."},{"question":"Will 3RV2011-0HA20 drop into a panel that was specified around 3RV2011-0BA20 without rewiring?","answer":"Both are Size S00 motor protection circuit breakers with the same DIN rail footprint and spring-loaded terminal arrangement, so the mechanical fit and terminal spacing are identical. The difference is in the trip class and breaking capacity — verify the 3RV2011-0BA20's specific ratings against your application before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0HA20","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0HA20 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}