{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0JA25-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0JA25-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0JA25-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0JA25-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV2011-0JA25-ZW97, CLASS 10 trip, 100 kA SCCR at 400 V, phase failure detection, spring-loaded terminals, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"The unit also includes phase failure detection, which drops the load if one phase is lost, preventing single-phasing damage on three-phase motors. Rated for 0.2 kW at 230 V and 0.5 hp at 575/600 V, this breaker suits smaller motor loads — pumps, fans, conveyors — in control panels where space is tight. ## Short-circuit ratings and coordination The 3RV2011-0JA25-ZW97 carries a 100 kA rated short-circuit breaking capacity at 400 V, 480 V, 500 V, and 690 V. At 240 V the rating is also 100 kA. This level of interrupting capacity typically allows Type 2 coordination with upstream contactors, minimizing damage on a fault. The built-in auxiliary contacts are rated 1 A at 24 V, 0.5 A at 120 V, 0.5 A at 125 V, and 0.5 A at 230 V. At 60 V the rating drops to 0.15 A. These feed status signals back to a PLC or indicator lamp — enough for 24 VDC control circuits common in modern panels, but the 60 V figure is a derating point worth noting if you're running a 48 VDC control bus. Clearance requirements: 50 mm upwards, 50 mm downwards, 30 mm at the sides for heat dissipation and arc clearance.","metaTitle":"Siemens 3RV2011-0JA25-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens SIRIUS 3RV2011-0JA25-ZW97 motor protection circuit breaker. CLASS 10 trip, 100 kA SCCR at 400 V, phase failure detection, spring-loaded terminals, DIN rail mount. Current l","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"106 mm","Upwards":"50 mm","at 24 V":"1 A","at 60 V":"0.15 A","Forwards":"0 mm","at 120 V":"0.5 A","at 125 V":"0.5 A","at 230 V":"0.5 A","at 500 V":"gL/gG 10 A","at 690 V":"gL/gG 10 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.2 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"1 A","at 500 V rated value":"100 kA","at 600 V rated value":"1 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","at 575/600 V rated value":"0.5 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 3 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"3,0 x 0,5 mm","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"1 A","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"1 A","at AWG cables for main contacts":"2x (20 ... 12)","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"spring-loaded terminals","Between Main And Auxiliary Circuit":"400 V","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 14)","at AC in hot operating state per pole":"2.4 W","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","Finely Stranded Without Core End Processing":"2x (0.5 ... 1.5 mm²)","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Switching Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","contact rating of auxiliary contacts according to UL":"C300 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"13 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.7 ... 1 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2b94cce8662912314a5e2bf4c49c162f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=622681&mlfb=3RV2011-0JA25-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0JA25-ZW97/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV2011-0JA25-ZW97 and get a price?","answer":"This part is sourced to order against an RFQ through independent distribution channels. Submit an RFQ for current pricing and availability — figures are confirmed at quote time, not listed here."},{"question":"Will 3RV2011-0JA25-ZW97 drop into a panel specified for 3RV2011-0BA20 without rewiring?","answer":"Both are SIRIUS 3RV2 motor protection breakers with the same 45 mm width and DIN-rail mounting. The -0JA25-ZW97 variant includes spring-loaded terminals and a different auxiliary contact configuration, so check the terminal layout against your existing wiring plan. The footprint and rail clip are identical."},{"question":"What compliance documentation does Siemens provide for this part?","answer":"As a standard SIRIUS catalog product, Siemens provides a declaration of conformity for IEC/EN 60947, UL/CSA listing, and RoHS/REACH compliance documentation. Specific certificates are available on request with the order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0JA25-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0JA25-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}