{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV2011-0KA10-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV2011-0KA10-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RV2011-0KA10-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0KA10-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV2011-0KA10-ZW97 motor protection circuit breaker, Trip Class 10, 100 kA breaking capacity at 400 V AC, 45 mm width, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"## Motor protection circuit breaker with Trip Class 10 and 100 kA breaking capacity The 100 kA breaking capacity at 400 V AC and at 240 V, 500 V, and 690 V means this breaker can safely interrupt fault currents up to that level without upstream fuses or a larger breaker — a key spec for high-fault-capacity industrial panels where the available short-circuit current at the motor starter exceeds 50 kA. The 45 mm width and 97 mm depth fit the standard SIRIUS 3RV2 footprint, and the screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715 means it clips directly into a panel alongside contactors and overload relays without extra brackets. ## Mounting and integration into a motor starter panel The screw-type terminals on the main current circuit accept 2× (0.75 to 2.5 mm²) solid or stranded, or 2× 4 mm², with M3 screws for the main contacts. Clearance distances: 50 mm upwards and downwards, 30 mm at the side, 0 mm forwards and backwards — the zero forward/backward clearance means it can be mounted flush against a backplate or enclosure wall without derating.","metaTitle":"Siemens 3RV2011-0KA10-ZW97 SIRIUS Motor Protection Circuit B","metaDescription":"Siemens 3RV2011-0KA10-ZW97 SIRIUS motor protection circuit breaker, Trip Class 10, 100 kA breaking capacity at 400 V, 45 mm wide, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"97 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","at 500 V":"gL/gG 16 A","at 690 V":"gL/gG 16 A","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"20 ... 690 V","During Storage":"-50 ... +80 °C","at AC-3 maximum":"15 1/h","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"15 1/h","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","at 230 V rated value":"0.2 kW","at 240 V rated value":"100 kA","at 400 V rated value":"100 kA","at 480 V rated value":"1.25 A","at 500 V rated value":"100 kA","at 600 V rated value":"1.25 A","at 690 V rated value":"100 kA","Design Of The Product":"For motor protection","Ground Fault Detection":"No","Phase Failure Detection":"Yes","For Main Current Circuit":"screw-type terminals","at 460/480 V rated value":"1 hp","at 575/600 V rated value":"0.5 hp","at AC at 240 V rated value":"100 kA","at AC at 400 V rated value":"100 kA","at AC at 500 V rated value":"100 kA","at AC at 690 V rated value":"100 kA","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Circuit-Breaker":"S00","Size Of The Screwdriver Tip":"Pozidriv size 2","at AC-3 rated value maximum":"690 V","Of The Main Contacts Typical":"100 000","at AC in hot operating state":"7.25 W","at AC-3 at 400 V rated value":"1.25 A","at AC-3e rated value maximum":"690 V","Of Auxiliary Contacts Typical":"100 000","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"1.25 A","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"1.25 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (18 ... 14), 2x 12","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Handle","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.4 W","With Side-By-Side Mounting At The Side":"0 mm","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","with low demand rate according to SN 31920":"50 FIT","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","with high demand rate according to SN 31920":"50 %","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"25g / 11 ms","Electrical Endurance (Operating Cycles) Typical":"100 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"16 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.9 ... 1.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d4312db130ed7688329ac328ea3e1de9.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=571869&mlfb=3RV2011-0KA10-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV2011-0KA10-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3RV2011-0KA10-ZW97 at 400 V?","answer":"The breaking capacity is 100 kA at 400 V AC, and the same 100 kA rating applies at 240 V, 500 V, and 690 V."},{"question":"Will 3RV2011-0KA10-ZW97 drop into a panel specified around 3RV1011-0GA10?","answer":"The 3RV2011-0KA10-ZW97 shares the same 45 mm width and DIN rail mounting as the 3RV1011 family, so it will physically fit the same panel footprint and rail. However, the 3RV2011 series is the current generation with a 100 kA breaking capacity, while the 3RV1011 series is an older design — verify the available fault current at the panel location to confirm the breaker's interrupting rating is sufficient."},{"question":"Where can I buy 3RV2011-0KA10-ZW97?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV2011-0KA10-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV2011-0KA10-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}